Miniaturized thin-layer radial flow cell with interdigitated ring-shaped microarray electrode used as amperometric detector for capillary electrophoresis

被引:22
作者
Liu, ZM
Niwa, O
Kurita, R
Horiuchi, T
机构
[1] Nippon Telegraph & Tel Corp, Lifestyle & Environm Technol Labs, Atsugi, Kanagawa 2430198, Japan
[2] NTT Adv Technol Corp, Atsugi, Kanagawa 2430198, Japan
关键词
instrumentation; electrochemical detection; detection; electrophoresis; electrodes; flow cell; catecholamines;
D O I
10.1016/S0021-9673(00)00632-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A chip-type thin-layer radial flow cell was developed as an amperometric detector for capillary electrophoresis. We fabricated a carbon film-based interdigitated ring-shaped array (IDRA) microelectrode with a 2 mu m bandwidth and an almost 1 mu m gap on a glass plate and used it as a working electrode. A fused-silica capillary was arranged above the IDRA electrode using a guide hole drilled through the acryl plate that formed the flow cell lid. A flow channel for use in connecting the outlet capillary was also fabricated in the acryl plate. We characterized the analytical performance of the IDRA electrode in the microchip flow cell in terms of linear concentration range, sensitivity and concentration detection limit. We achieved a collection efficiency and catechol redox cycle at the IDRA microelectrode of 65% and 1.71, respectively, and thus a high sensitivity and low detection limit of 392.9 pA/mu M and 15 nM for dopamine hydrochloride. We examined the reproducibility of the detector and found that the run-to-run and detector-to-detector relative standard deviations were both less than 10%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 35 条
[1]   ELECTROCHEMICAL RESPONSE AT MICROARRAY ELECTRODES IN FLOWING STREAMS AND DETERMINATION OF CATECHOLAMINES [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2206-2210
[2]   Electrochemical determination of carbohydrates: Enzyme electrodes and amperometric detection in liquid chromatography and capillary electrophoresis [J].
Baldwin, RP .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :69-81
[3]  
Beale SC, 1998, ANAL CHEM, V70, p279R
[4]   Parallel-opposed dual-electrode detector with recycling amperometric enhancement for capillary electrophoresis [J].
Chen, DC ;
Chang, SS ;
Chen, CH .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3200-3205
[5]   CAPILLARY ELECTROPHORESIS WITH AMPEROMETRIC DETECTION USING A POROUS CELLULOSE-ACETATE JOINT [J].
CHEN, IC ;
WHANG, CW .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :208-212
[6]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[7]   Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection [J].
Fermier, AM ;
Gostkowski, ML ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1661-1664
[8]  
FLEISCHMANN F, 1987, ULTRAMICROELECTRODES
[9]   Continuous separations with microfabricated electrophoresis-electrochemical array detection [J].
Gavin, PF ;
Ewing, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (37) :8932-8936
[10]   Characterization of electrochemical array detection for continuous channel electrophoretic separations in micrometer and submicrometer channels [J].
Gavin, PF ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3838-3845