In vivo fluoroscopic analysis of the normal human knee

被引:345
作者
Komistek, RD
Dennis, DA
Mahfouz, M
机构
[1] Rocky Mt Musculoskeletal Res Lab, Denver, CO USA
[2] Colorado Sch Mines, Div Engn, Golden, CO 80401 USA
关键词
D O I
10.1097/01.blo.0000062384.79828.3b
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objective of the current study was to use fluoroscopy and computed tomography to accurately determine the three-dimensional, in vivo, weightbearing kinematics of five normal knees. Three-dimensional computer-aided design models of each subject's femur and tibia were recreated from the three-dimensional computed tomography bone density data. Three-dimensional motions for each subject then were determined for five weightbearing activities. During gait, the lateral condyle experienced -4.3 mm (range, -1.9--10.3 mm) of average motion, whereas the medial condyle moved only -0.9 mm (range, 3.4--5.8 mm). One subject experienced 5.8 mm of medial condyle motion. On average, during deep flexion activities, subjects experienced -12.7 mm (range, 1.4--29.8 mm) of lateral condyle motion, whereas the medial condyle motion only was -2.9 mm (range, 3.0--9.0 mm). One subject experienced 5.8 and 9.0 mm of medial condyle motion during gait and a deep knee bend, respectively leading to the occurrence of a lateral pivot motion. During the deep flexion activities, the subjects experienced significantly more axial rotation (> 13degrees) than gait (< 5degrees). During all five activities, the lateral condyle experienced significantly more anteroposterior translation, leading to axial rotation of the tibia relative to the femur.
引用
收藏
页码:69 / 81
页数:13
相关论文
共 29 条
[1]  
Andriacchi T P, 1986, J Arthroplasty, V1, P211, DOI 10.1016/S0883-5403(86)80033-X
[2]   FUNCTIONAL-ANALYSIS OF PRE-KNEE AND POST-KNEE SURGERY - TOTAL KNEE ARTHROPLASTY AND ACL RECONSTRUCTION [J].
ANDRIACCHI, TP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :575-581
[3]  
ANDRIACCHI TP, 1994, JAMA-J AM MED ASSOC, V271, P1349
[4]   JUSTIFICATION OF TRIAXIAL GONIOMETER FOR THE MEASUREMENT OF JOINT ROTATION [J].
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1980, 13 (12) :989-+
[5]  
DENNIS DA, 1996, CLIN ORTHOP RELAT R, V331, P107
[6]  
DENNIS DA, 1998, CLIN ORTHOP RELAT R, V356, P47
[7]   INTERACTION BETWEEN INTRINSIC KNEE MECHANICS AND THE KNEE EXTENSOR MECHANISM [J].
DRAGANICH, LF ;
ANDRIACCHI, TP ;
ANDERSSON, GBJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (04) :539-547
[8]   AN INVITRO BIOMECHANICAL EVALUATION OF ANTERIOR-POSTERIOR MOTION OF THE KNEE - TIBIAL DISPLACEMENT, ROTATION, AND TORQUE [J].
FUKUBAYASHI, T ;
TORZILLI, PA ;
SHERMAN, MF ;
WARREN, RF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) :258-264
[9]   THE FREEMAN-SWANSON ICLH TOTAL KNEE ARTHROPLASTY - COMPLICATIONS AND PROBLEMS [J].
GOLDBERG, VM ;
HENDERSON, BT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (08) :1338-1344
[10]   Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy [J].
Hoff, WA ;
Komistek, RD ;
Dennis, DA ;
Gabriel, SM ;
Walker, SA .
CLINICAL BIOMECHANICS, 1998, 13 (07) :455-472