Development of a novel carbon paste electrode containing a natural zeolite for the voltammetric determination of copper

被引:54
作者
Alpat, SK [1 ]
Yuksel, U
Akcay, H
机构
[1] Dokuz Eylul Univ, Dept Chem Educ, Izmir, Turkey
[2] Ege Univ, Dept Chem, Izmir, Turkey
关键词
natural zeolite; voltammetry; carbon paste electrode; copper; real samples;
D O I
10.1016/j.elecom.2004.11.017
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Natural zeolite modified carbon paste electrode (NZMCPE) was developed for the voltammetric determination of Cu (11). Copper (11) was selectively preconcentrated, at open circuit, on the NZMCPE. The measurements were carried out by using differential pulse cathodic stripping voltammetry. Linear response to copper (II) was found in the 5.0 x 10(-8) - 5.0 x 10(-6) M (r: 0.9990) concentration range, with a detection limit estimated at 1.5 x 10(-8) M. The multiple determinations (n = 6), following a preconcentration detection-regeneration cycle, shown a relative standard deviation of 2.22% at Cu (II) concentration of 2.0 x 10(-6) M. The developed method was also applied to the determination of copper in two model solutions and two real samples. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 12 条
[1]   Determination of copper by zeolite molecular sieve modified electrode [J].
Chen, B ;
Goh, NK ;
Chia, LS .
ELECTROCHIMICA ACTA, 1997, 42 (04) :595-604
[2]   DETERMINATION OF MERCURY(II) USING A MODIFIED ELECTRODE WITH ZEOLITE [J].
HERNANDEZ, P ;
ALDA, E ;
HERNANDEZ, L .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 327 (07) :676-678
[3]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22
[4]   COPPER-ZEOLITE-MODIFIED ELECTRODES - AN INTRAZEOLITE ION-TRANSPORT MECHANISM [J].
LI, JW ;
CALZAFERRI, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 377 (1-2) :163-175
[5]   Zeolite-modified electrodes: Intra- versus extrazeolite electron transfer [J].
Senaratne, C ;
Zhang, J ;
Baker, MD ;
Bessel, CA ;
Rolison, DR .
JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (14) :5849-5862
[6]   VOLTAMMETRIC RESPONSE OF ZEOLITE-MODIFIED ELECTRODES [J].
SHAW, BR ;
CREASY, KE ;
LANCZYCKI, CJ ;
SARGEANT, JA ;
TIRHADO, M .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (04) :869-876
[7]   Zeolite-modified electrodes: Analytical applications and prospects [J].
Walcarius, A .
ELECTROANALYSIS, 1996, 8 (11) :971-986
[8]   Zeolite-modified electrodes in electroanalytical chemistry [J].
Walcarius, A .
ANALYTICA CHIMICA ACTA, 1999, 384 (01) :1-16
[9]   Factors affecting the analytical applications of zeolite-modified electrodes - Preconcentration of electroactive species [J].
Walcarius, A ;
Barbaise, T ;
Bessiere, J .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :61-76
[10]   Voltammetric response of the hexammino-ruthenium complex incorporated in zeolite-modified carbon paste electrode [J].
Walcarius, A ;
Lamberts, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 422 (1-2) :77-89