Effect of caged fluorescent dye on the electroosmotic mobility in microchannels

被引:38
作者
Ross, D [1 ]
Locascio, LE
机构
[1] NIST, Proc Measurement Div, Gaithersburg, MD 20899 USA
[2] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
关键词
D O I
10.1021/ac026277u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on measurements of electroosmotic mobility in polymer microchannels and silica capillaries with and without the addition of a caged fluorescein dye to the buffer. For PMMA microchannels, the mobility was found to increase from (2.6 +/- 0. 1) x 10(-4) cm(2) V-1 s(-1) to (4.6 +/- 0.1) x 10(-4) cm(2) V-1 s(-1) upon addition of 1.2 mmol/L of caged dye. For PC microchannels, the mobility increased from (4.3 +/- 0.2) x 10(-4) cm(2) V-1 s(-1) to (5.4 +/- 0. 1) x 10(-4) cm(2) V-1 s(-1) upon addition of caged dye. For PDMS microchannels, the mobility increased from (4.3 +/- 0.2) x 10(-4) cm(2) V-1 s(-1) to (6.4 +/- 10.5) x 10(-4) cm(2) V-1 s(-1) upon addition of caged dye. For fused-silica capillaries, the mobility ((5.5 +/- 0.2) x 10(-4) cm(2) V-1 s(-1)) was unaffected by the addition of the caged dye.
引用
收藏
页码:1218 / 1220
页数:3
相关论文
共 17 条
[1]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[2]   Surface modification of poly(methyl methacrylate) used in the fabrication of microanalytical devices [J].
Henry, AC ;
Tutt, TJ ;
Galloway, M ;
Davidson, YY ;
McWhorter, CS ;
Soper, SA ;
McCarley, RL .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5331-5337
[3]   Electroosmotic capillary flow with nonuniform zeta potential [J].
Herr, AE ;
Molho, JI ;
Santiago, JG ;
Mungal, MG ;
Kenny, TW ;
Garguilo, MG .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :1053-1057
[4]   CURRENT-MONITORING METHOD FOR MEASURING THE ELECTROOSMOTIC FLOW-RATE IN CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1837-1838
[5]   Laser modification of preformed polymer microchannels: Application to reduce band broadening around turns subject to electrokinetic flow [J].
Johnson, TJ ;
Ross, D ;
Gaitan, M ;
Locascio, LE .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3656-3661
[6]  
LEMPERT WR, 1995, EXP FLUIDS, V18, P249
[7]   Fabrication of plastic microfluid channels by imprinting methods [J].
Martynova, L ;
Locascio, LE ;
Gaitan, M ;
Kramer, GW ;
Christensen, RG ;
MacCrehan, WA .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4783-4789
[8]   Optimization of turn geometries for microchip electrophoresis [J].
Molho, JI ;
Herr, AE ;
Mosier, BP ;
Santiago, JG ;
Kenny, TW ;
Brennen, RA ;
Gordon, GB ;
Mohammadi, B .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1350-1360
[9]  
MOLHO JI, 2001, THESIS STANFORD U ST
[10]  
Ocvirk G, 2000, ELECTROPHORESIS, V21, P107, DOI 10.1002/(SICI)1522-2683(20000101)21:1<107::AID-ELPS107>3.0.CO