Improving quantitative measurements for the evaporative light scattering detector

被引:82
作者
Mathews, BT
Higginson, PD
Lyons, R
Mitchell, JC
Sach, NW
Snowden, MJ
Taylor, MR
Wright, AG
机构
[1] Nat Resources Inst, Chatham ME4 4TB, Kent, England
[2] Pfizer Global Res & Dev Inst, Sandwich CT13 9NJ, Kent, England
关键词
column liquid chromatography; evaporate light-scattering detector; detector calibration;
D O I
10.1365/s10337-004-0441-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A study was undertaken to evaluate a generic calibration routine for the evaporative light scattering detector (ELSD). The calibration routine was designed for use with gradient HPLC-ELSD in order to adjust for the effects of the non-linear response curve and the variation in response with mobile phase composition. A single calibrant was employed with an automated injection protocol to enable rapid capture of the calibration information. The study assessed the validity of the calibration method and the suitability of the calibrant for the quantitation and purity estimation of a series of structurally unrelated compounds. The calibration routine was demonstrated to improve the quality of quantitative estimates and purity estimates given by the gradient HPLC-ELSD. The average error in quantitation for the series of materials was 8.3%.
引用
收藏
页码:625 / 633
页数:9
相关论文
共 10 条
[1]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[2]   Evaporative light-scattering detection coupled to microcolumn liquid chromatography for the analysis of underivatized amino acids: Sensitivity, linearity of response and comparisons with UV absorbance detection [J].
Cobb, Z ;
Shaw, PN ;
Lloyd, LL ;
Wrench, N ;
Barrett, DA .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (04) :169-175
[3]   Evaluation of evaporative light-scattering detector for combinatorial library quantitation by reversed phase HPLC [J].
Fang, LL ;
Wan, M ;
Pennacchio, M ;
Pan, JM .
JOURNAL OF COMBINATORIAL CHEMISTRY, 2000, 2 (03) :254-257
[4]  
Fang LL, 2000, BIOTECHNOL BIOENG, V71, P162, DOI 10.1002/1097-0290(2000)71:2<162::AID-BIT1006>3.0.CO
[5]  
2-A
[6]   INFLUENCE OF VARIOUS PARAMETERS ON THE RESPONSE FACTORS OF THE EVAPORATIVE LIGHT-SCATTERING DETECTOR FOR A NUMBER OF NON-VOLATILE COMPOUNDS [J].
GUIOCHON, G ;
MOYSAN, A ;
HOLLEY, C .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (12) :2547-2570
[7]   PRINCIPLES OF OPERATION OF AN EVAPORATIVE LIGHT-SCATTERING DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
MOUREY, TH ;
OPPENHEIMER, LE .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2427-2434
[8]   EFFECTS OF THE NATURE OF THE SOLVENT AND SOLUTES ON THE RESPONSE OF A LIGHT-SCATTERING DETECTOR [J].
RIGHEZZA, M ;
GUIOCHON, G .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (9-10) :1967-2004
[9]   EFFECT OF THE WAVELENGTH OF THE LASER-BEAM ON THE RESPONSE OF AN EVAPORATIVE LIGHT-SCATTERING DETECTOR [J].
RIGHEZZA, M ;
GUIOCHON, G .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (13) :2709-2729
[10]  
Young CS, 2003, LC GC EUR, V16, P132