Tumour size measurement in an oncology clinical trial: Comparison between off-site and on-site measurements

被引:33
作者
Belton, AL
Saini, S
Liebermann, K
Boland, GW
Halpern, EF
机构
[1] Radiol Associates Wausau, Wausau, WI 54401 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
[4] WorldCare Inc, Cambridge, MA USA
关键词
diagnostic radiology; observer performance; images; interpretation; efficacy study;
D O I
10.1016/S0009-9260(02)00577-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the degree of variability between lesion measurements obtained by a single observer compared with multiple observers, and in selected cases evaluate which of the two measurements more accurately represented the lesion size. MATERIALS AND METHODS: In this study we compared the performance of a single off-site observer to multiple on-site observers during measurement of 300 abdominal and thoracic lesions. Lesion measurements that were larger than 1 cm(2), differed by more than 50%, but by less than 100%, were compared by a single adjudicator, who was blinded to the measurement source (n = 46) RESULTS: Measurements of the 300 lesions differed by an average of 109% (SD 251%). Of 266 lesions larger than 1 cm(2), results of the single observer compared with multiple observers differed by more than 10% for 249 lesions, more than 30% for 169 lesions, more than 50% for 126 lesions, and more than 100% for 66 lesions. Forty-six lesions were compared by the adjudicator. The adjudicator selected the measurement of the single observer for 37 lesions (80.4%), and the measurement determined by one of the multiple observers for nine lesions (19.6%; p = 0.00002). CONCLUSION: Measurement of lesion size by a single observer compared with multiple observers reveals a high degree of variability. An adjudicator selected the measurement of the single observer more frequently than that of multiple observers, with statistical significance. These findings suggest that studies designed to quantify imaging features should limit the number of observers. (C) 2003 Published by Elsevier Science Ltd on behalf of The Royal College of Radiologists.
引用
收藏
页码:311 / 314
页数:4
相关论文
共 10 条
[1]   Multicenter phase II study of capecitabine in paclitaxel-refractory metastatic breast cancer [J].
Blum, JL ;
Jones, SE ;
Buzdar, AU ;
LoRusso, PM ;
Kuter, I ;
Vogel, C ;
Osterwalder, B ;
Burger, HU ;
Brown, CS ;
Griffin, T .
JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (02) :485-493
[2]  
BUYSE M, 1996, 6 INT C ANT TREATM F, P35
[3]   Capecitabine [J].
Dooley, M ;
Goa, KL .
DRUGS, 1999, 58 (01) :69-76
[4]  
HAMBLIN TJ, 1939, EUR J CANC CLIN O S3, V25, pS7
[5]   COMPARISON OF LOCAL VERSUS CENTRAL TUMOR MEASUREMENTS IN A MULTICENTER CANCER TRIAL [J].
HENDERSON, WG ;
ZACHARSKI, LR ;
SPIEGEL, PK ;
RICKLES, FR ;
FORMAN, WB ;
CORNELL, CJ ;
FORCIER, RJ ;
EDWARDS, RL ;
HEADLEY, E ;
KIM, SH ;
ODONNELL, JF ;
ODELL, R ;
TORNYOS, K ;
KWAAN, HC .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1984, 7 (06) :705-712
[6]   AN ATTEMPT TO QUANTIFY MAGNETIC-RESONANCE IMAGING IN MULTIPLE-SCLEROSIS - CORRELATION WITH CLINICAL-PARAMETERS [J].
KAPPOS, L ;
STADT, D ;
KEIL, W ;
RATZKA, M ;
HEITZER, T ;
SCHNEIDERBANGERGRYGIER, S .
NEUROSURGICAL REVIEW, 1987, 10 (02) :133-135
[7]  
MOERTEL CG, 1976, CANCER, V38, P388, DOI 10.1002/1097-0142(197607)38:1<388::AID-CNCR2820380156>3.0.CO
[8]  
2-A
[9]  
Morris L, 1998, Oncology (Williston Park), V12, P139
[10]   Radiology's Achilles' heel: error and variation in the interpretation of the Rontgen image [J].
Robinson, PJA .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (839) :1085-1098