Sonography of full-thickness supraspinatus tears: Comparison of patient positioning technique with surgical correlation

被引:44
作者
Ferri, M
Finlay, K
Popowich, T
Stamp, G
Schuringa, P
Friedman, L
机构
[1] McMaster Univ, Dept Diagnost Imaging, Hamilton, ON L8N 1Y7, Canada
[2] Hamilton Hlth Sci, Hamilton, ON L8V 1Y7, Canada
[3] Henderson Gen Hosp, Hamilton Hlth Sci, Hamilton, ON L8V 1C3, Canada
[4] St Josephs Hosp, Dept Diagnost Imaging, Hamilton, ON L8N 4A6, Canada
[5] Guelph Gen Hosp, Dept Orthopaed Surg, Guelph, ON N1E 4J4, Canada
[6] St Marys Hosp, Dept Orthopaed Surg, Kitchener, ON N2M 1B2, Canada
关键词
D O I
10.2214/ajr.184.1.01840180
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. Sonography has become a popular technique for the assessment of musculoskeletal disorders. Patient positioning is crucial to a thorough and accurate assessment of rotator cuff tendons. Two positions, the Crass and modified Crass, have been routinely used in the research and clinical settings to examine the supraspinatus tendon. Our study was a prospective trial to determine whether the Crass or the modified Crass position affords the most accurate measure of supraspinatus tears when compared with surgical findings. SUBJECTS AND METHODS. Twenty-one patients with full-thickness supraspinatus tears underwent shoulder sonography in both the Crass and the modified Crass positions. Measurements of supraspinatus tears were performed in the sagittal and transverse dimensions. Patients subsequently underwent either arthroscopic or open supraspinatus repair. Intraoperative measurements were made in two dimensions and were compared with sonographic findings. RESULTS. Sonography had 100% specificity in detecting full-thickness supraspinatus tears. No statistically significant difference was seen between the size of supraspinatus tears in the Crass and modified Crass positions and surgical findings in the transverse plane (p = 0.55 and 0.61, respectively). In the sagittal dimension, no statistically significant difference was seen between surgical findings and the Crass position (p = 0.14); however, a difference existed when the modified Crass position was used (p = 0.03). CONCLUSION. Sonography reliably detects and quantifies supraspinatus tears. Both the Crass and the modified Crass positions reflected the true size of supraspinatus tears in the transverse plane. In the sagittal plane, the Crass position is the more useful to quantify supraspinatus tears because the modified Crass position overestimates the size of such tears.
引用
收藏
页码:180 / 184
页数:5
相关论文
共 16 条
[1]
AHOVUO J, 1989, ACTA RADIOL, V30, P253
[2]
Ultrasonography of the shoulder [J].
Bouffard, JA ;
Lee, SM ;
Dhanju, J .
SEMINARS IN ULTRASOUND CT AND MRI, 2000, 21 (03) :164-191
[3]
THE HYPEREXTENDED INTERNAL-ROTATION VIEW IN ROTATOR CUFF ULTRASONOGRAPHY [J].
CRASS, JR ;
CRAIG, EV ;
FEINBERG, SB .
JOURNAL OF CLINICAL ULTRASOUND, 1987, 15 (06) :416-420
[4]
ULTRASONOGRAPHY OF ROTATOR CUFF TEARS - A REVIEW OF 500 DIAGNOSTIC STUDIES [J].
CRASS, JR ;
CRAIG, EV ;
FEINBERG, SB .
JOURNAL OF CLINICAL ULTRASOUND, 1988, 16 (05) :313-327
[5]
Site and size of rotator-cuff tear - Findings at ultrasound, double-contrast arthrography, and computed tomography arthrography with surgical correlation [J].
Farin, PU ;
Kaukanen, E ;
Jaroma, H ;
Vaatainen, U ;
Miettinen, H ;
Soimakallio, S .
INVESTIGATIVE RADIOLOGY, 1996, 31 (07) :387-394
[6]
Friedman L, 2002, CAN ASSOC RADIOL J, V53, P22
[7]
ROTATOR CUFF TEARS - CORRELATION OF SONOGRAPHIC AND SURGICAL FINDINGS [J].
HODLER, J ;
FRETZ, CJ ;
TERRIER, F ;
GERBER, C .
RADIOLOGY, 1988, 169 (03) :791-794
[8]
US EVALUATION OF THE ROTATOR CUFF [J].
MACK, LA ;
MATSEN, FA ;
KILCOYNE, RF ;
DAVIES, PK ;
SICKLER, ME .
RADIOLOGY, 1985, 157 (01) :205-209
[9]
MIDDLETON WD, 1992, RADIOL CLIN N AM, V30, P927
[10]
ULTRASONOGRAPHY AND ARTHROGRAPHY IN THE DIAGNOSIS OF TEARS OF THE ROTATOR CUFF [J].
PAAVOLAINEN, P ;
AHOVUO, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :335-340