Millimeter-resolution E-field probe for isotropic measurement in lossy media between 100 MHz and 20 GHz

被引:27
作者
Pokovic, K [1 ]
Schmid, T [1 ]
Kuster, N [1 ]
机构
[1] Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
关键词
dosimetry; electric field probe; radio frequency measurements; specific absorption rate (SAR);
D O I
10.1109/19.863941
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently, most advanced isotropic E-field probes for near-field measurements in lossy dielectric media have a tip diameter of typically la mm, housing three 2-3 mm long sensors. Although these probes are very well suited for many applications, their general use is constrained by several limitations: 1) upper frequency range of <4 GHz In tissue simulating liquids, 2) spatial resolution of a few millimeters, 3) unsuitable for measurements closer than 3-5 mm from any media boundary (boundary effects); and therefore 4) inapplicable for assessment of the induced held strengths in structures of a few millimeters, On the other hand, many current acid future research projects require evaluation of the field distributions for frequencies larger than a few gigahertz, for measurements within small structures (e.g., in in vitro and in vivo experiments), for evaluations of special physical interactions such as strongly nonhomogeneous field distributions or characterization of larger probes, etc, A new probe has been developed which is applicable for frequencies well above 10 GHz in tissue-like media and provides a spatial resolution of at least 1 mm, Although it is a one sensor probe, it has been designed such that the isotropic measurement (spherical isotropy: <0.2 dB) can be obtained simply by taking three measurements each shifted by 120 degrees rotation around the probe's axis. The probe has been fully characterized and tested in various applications.
引用
收藏
页码:873 / 878
页数:6
相关论文
共 13 条
[1]   Spontaneous and nitrosourea-induced primary tumors of the central nervous system in Fischer 344 rats chronically exposed to 836 MHz modulated microwaves [J].
Adey, WR ;
Byus, CV ;
Cain, CD ;
Higgins, RJ ;
Jones, RA ;
Kean, CJ ;
Kuster, N ;
MacMurray, A ;
Stagg, RB ;
Zimmerman, G ;
Phillips, JL ;
Haggren, W .
RADIATION RESEARCH, 1999, 152 (03) :293-302
[2]  
ADEY WR, J CANC RES
[3]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[4]  
[Anonymous], 1992, C9511991 IEEE
[5]   AN IMPLANTABLE ELECTRIC-FIELD PROBE OF SUBMILLIMETER DIMENSIONS [J].
BATCHMAN, TE ;
GIMPELSON, G .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1983, 31 (09) :745-751
[6]   Exposure setup to test effects of wireless communications systems on the CNS [J].
Burkhardt, M ;
Spinelli, Y ;
Kuster, N .
HEALTH PHYSICS, 1997, 73 (05) :770-778
[7]  
Burkhardt M, 1996, BIOELECTROMAGNETICS, V17, P483, DOI 10.1002/(SICI)1521-186X(1996)17:6<483::AID-BEM8>3.0.CO
[8]  
2-#
[9]  
KUSTER N, 1997, MOBILE COMMUNICATION
[10]   Broadband calibration of E-field probes in lossy media [J].
Meier, K ;
Burkhardt, M ;
Schmid, T ;
Kuster, N .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1954-1962