Use of pH gradients in continuous-flow systems and multivariate regression techniques applied to the determination of methionine and cysteine in pharmaceuticals

被引:37
作者
Blasco, F [1 ]
MedinaHernandez, MJ [1 ]
Sagrado, S [1 ]
机构
[1] UNIV VALENCIA,FAC FARM,DEPT QUIM ANAL,E-46100 BURJASSOT,VALENCIA,SPAIN
关键词
partial least-squares regression; multicomponent analysis; methionine; cysteine; flow injection; pH gradients; pharmaceuticals;
D O I
10.1016/S0003-2670(97)00063-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous spectrophotometric determination of methionine and cysteine in presence of cystine and other compounds in pharmaceuticals, using a multivariate calibration method, was studied. The method is based on the reaction between the analytes and the o-phthalaldehyde-N-acetyl-L-cysteine (OPA-NAC) reagent performed in a continuous-flow system (FI). The FI system allows the generation of a local pH gradient in order to produce spectral and/or kinetic changes in the W-Vis spectra of the amino acid-OPA-NAC derivatives. This information is used to improve the prediction ability of the Partial Least-Squares (PLS) models. The performance of two FI assemblies, the selection of variables and the pretreatment of the data were studied. A series of eighteen synthetic solutions containing different concentrations of methionine, cysteine and cystine was prepared and used as a calibration set to study the PLS models. In addition, solutions of a commercial formulation containing the three amino acids were prepared and the content of methionine and cysteine was predicted. The results obtained using the PLS models were compared with those obtained using an HPLC method.
引用
收藏
页码:151 / 159
页数:9
相关论文
共 13 条
[1]   STUDIES ON THE FORMATION AND STABILITY OF ISOINDOLES DERIVED FROM AMINO-ACIDS, ORTHO-PHTHALALDEHYDE AND N-ACETYL-L-CYSTEINE [J].
ALVAREZCOQUE, MCG ;
HERNANDEZ, MJM ;
CAMANAS, RMV ;
FERNANDEZ, CM .
ANALYTICAL BIOCHEMISTRY, 1989, 180 (01) :172-176
[2]  
[Anonymous], CHEM BIOCH AMINO ACI
[3]   Indicator reaction for sensitive kinetic micro-determination of cysteine and cystine in a mixture without prior separation [J].
Giannousios, A ;
Papadopoulos, C .
ANALYST, 1996, 121 (04) :413-417
[4]  
HEANG SK, 1983, INT J ENVIRON AN CH, V15, P309
[5]   DETERMINATION OF CYSTEINE PLUS HALF-CYSTINE IN PROTEIN AND PEPTIDE HYDROLYSATES - USE OF DITHIODIGLYCOLIC ACID AND PHENYLISOTHIOCYANATE DERIVATIZATION [J].
HOOGERHEIDE, JG ;
CAMPBELL, CM .
ANALYTICAL BIOCHEMISTRY, 1992, 201 (01) :146-151
[6]   APPLICATION OF A GENETIC ALGORITHM TO FEATURE-SELECTION UNDER FULL VALIDATION CONDITIONS AND TO OUTLIER DETECTION [J].
LEARDI, R .
JOURNAL OF CHEMOMETRICS, 1994, 8 (01) :65-79
[7]  
Reynolds JEF, 1993, MARTINDALE EXTRA PHA
[8]   FLUORESCENCE REACTION FOR AMINO ACIDS [J].
ROTH, M .
ANALYTICAL CHEMISTRY, 1971, 43 (07) :880-&
[9]   AUTOMATIC SIMULTANEOUS DETERMINATION OF CA AND MG IN NATURAL-WATERS WITH NO INTERFERENCE SEPARATION [J].
RUISANCHEZ, I ;
RIUS, A ;
LARRECHI, MS ;
CALLAO, MP ;
RIUS, FX .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 24 (01) :55-63
[10]  
SARWAR G, 1988, J ASSOC OFF ANA CHEM, V71, P1172