Mathematical framework for current density imaging due to discharge of electro-muscular disruption devices

被引:8
作者
Lee, Jeehyun [1 ]
Seo, Jin Keun [1 ]
Woo, Eung Je [1 ]
机构
[1] Yonsei Univ, Dept Math, Seoul 120749, South Korea
来源
ESAIM-MATHEMATICAL MODELLING AND NUMERICAL ANALYSIS-MODELISATION MATHEMATIQUE ET ANALYSE NUMERIQUE | 2007年 / 41卷 / 03期
关键词
electro-muscular disruption (EMD) device; electrical current density; Maxwell equations; non-smooth boundary; elliptic partial differential equations; corner singularity;
D O I
10.1051/m2an:2007030
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Electro-muscular disruption (EMD) devices such as TASER M26 and X26 have been used as a less-than-lethal weapon. Such EMD devices shoot a pair of darts toward an intended target to generate an incapacitating electrical shock. In the use of the EMD device, there have been controversial questions about its safety and effectiveness. To address these questions, we need to investigate the distribution of the current density J inside the target produced by the EMD device. One approach is to develop a computational model providing a quantitative and reliable analysis about the distribution of J. In this paper, we set up a mathematical model of a typical EMD shock, bearing in mind that we are aiming to compute the current density distribution inside the human body with a pair of inserted darts. The safety issue of TASER is directly related to the magnitude of vertical bar J vertical bar at the region of the darts where the current density J is highly concentrated. Hence,. ne computation of J near the dart is essential. For such numerical simulations, serious computational dificulties are encountered in dealing with the darts having two different very sharp corners, tip of needle and tip of barb. The boundary of a small fishhook-shaped dart inside a large computational domain and the presence of corner singularities require a very. ne mesh leading to a formidable amount of numerical computations. To circumvent these difficulties, we developed a multiple point source method of computing J. It has a potential to provide effective analysis and more accurate estimate of J near fishhook-shaped darts. Numerical experiments show that the MPSM is just fit for the study of EMD shocks.
引用
收藏
页码:447 / 459
页数:13
相关论文
共 27 条
  • [1] Optimal size estimates for the inverse conductivity problem with one measurement
    Alessandrini, G
    Rosset, E
    Seo, JK
    [J]. PROCEEDINGS OF THE AMERICAN MATHEMATICAL SOCIETY, 2000, 128 (01) : 53 - 64
  • [2] Alessandrini G., 1992, ANN SCUOLA NORM-SCI, V19, P567
  • [3] Electrical impedance tomography
    Cheney, M
    Isaacson, D
    Newell, JC
    [J]. SIAM REVIEW, 1999, 41 (01) : 85 - 101
  • [4] ISAKOV V, 1988, COMMUN PUR APPL MATH, V41, P856
  • [5] Ventricular fibrillation after stun-gun discharge.
    Kim, PJ
    Franklin, WH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (09) : 958 - 959
  • [6] ON A NONLINEAR PARTIAL DIFFERENTIAL EQUATION ARISING IN MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY
    Kim, Sungwhan
    Kwon, Ohin
    Seo, Jin Keun
    Yoon, Jeong-Rock
    [J]. SIAM JOURNAL ON MATHEMATICAL ANALYSIS, 2002, 34 (03) : 511 - 526
  • [7] Uniqueness and convergence of conductivity image reconstruction in magnetic resonance electrical impedance tomography
    Kim, YJ
    Kwon, O
    Se, JK
    Woo, EJ
    [J]. INVERSE PROBLEMS, 2003, 19 (05) : 1213 - 1225
  • [8] Kohn R, 1984, COMMUN PUR APPL MATH, V37, P113
  • [9] Magnetic resonance electrical impedance tomography (MREIT):: Simulation study of J-substitution algorithm
    Kwon, O
    Woo, EJ
    Yoon, JR
    Seo, JK
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (02) : 160 - 167
  • [10] LAUR D, 2004, EXCITED DELIRIUM ITS