Why reactions run away (Reprinted from IChemE Symposium Series 141, pg 361-366, 1997)

被引:23
作者
Etchells, JC [1 ]
机构
[1] Hlth & Safety Execut, Directorate Sci & Technol, Gas & Chem Proc Safety Unit, Boothle L20 3QZ, Merseyside, England
关键词
D O I
10.1021/op970031n
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Exothermic runaway incidents caused by poor understanding of the reaction chemistry and kinetics, under-rated control and safety backup systems, and inadequate procedures and training continue to be reported to the Health and Safety Executive (HSE). Although guidance and training to prevent such incidents is available, further work is needed to increase awareness of the problems, A recent HSE survey indicates that further information on relief system sizing is also required, A workbook on this topic is in preparation, and a leaflet, drawing attention to the hazards of exothermic runaway, is being published. Further action by the HSE to increase awareness is being considered.
引用
收藏
页码:435 / 437
页数:3
相关论文
共 10 条
[1]  
Barton J, 1997, Chemical Reaction Hazards: A Guide to Safety, V2nd
[2]  
Barton J. A., 1984, ICHEME S SERIES, V85
[3]  
Barton J.A., 1989, ICHEME S SERIES, V115
[4]  
ETCHELLS JC, 1993, IBC C ASS CONTR CHEM
[5]  
ETCHELLS JC, 1997, ICHEME S SERIES, V141, P361
[6]  
Fisher HG., 1992, Emergency Relief System Design Using DIERS Technology
[7]  
*I CHEM ENG, 1993, CONTR EX CHEM REACT
[8]  
ROGERS RL, 1994, C SCAL CHEM PROC SCI
[9]  
SINGH J, 1001996 HSE
[10]  
PROCESS SAF NEWS