Design issues and fatigue lifetime of hypervapotron elements of the JET neutral beam injectors

被引:8
作者
Ciric, D [1 ]
Akiba, M [1 ]
Falter, HD [1 ]
Martin, D [1 ]
Sato, K [1 ]
Yokoyama, K [1 ]
机构
[1] Jet Joint Undertaking, Abingdon OX14 3EA, Oxon, England
来源
18TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING | 1999年
关键词
D O I
10.1109/FUSION.1999.849867
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Recent results on high heat flux testing of hypervapotron beam stopping elements are discussed. Two issues are being addressed: a) fatigue lifetime of components presently used at JET, and b) performance of the optimised hypervapotron element for the new Box Scraper. Results of the tests confirmed that a) beam stopping elements installed at JET can be used with confidence for several more years, and b) new hypervapotron element can sustain higher power load (peak power density of 13 MW/m(2) and total power of 0.7 MW) at moderately increased water flow velocity.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 3 条
[1]  
BAXI C, 1992, JETP9256
[2]   An experimental and numerical investigation of post-CHF heat transfer for one-sided heat load with highly sub-cooled flow boiling [J].
Divavin, V ;
Tanchuk, V ;
Shrubok, A ;
Watson, R ;
Gonzalez, J .
FUSION ENGINEERING AND DESIGN, 1996, 31 (02) :189-200
[3]   Performance of hypervapotron beam-stopping elements at jet [J].
Falter, HD ;
Thompson, E .
FUSION TECHNOLOGY, 1996, 29 (04) :584-595