Use of surface plasmon resonance biosensor technology as a possible alternative to detect differences in binding of enantiomeric drug compounds to immobilized albumins

被引:34
作者
Ahmad, A [1 ]
Ramakrishnan, A [1 ]
McLean, MA [1 ]
Breau, AP [1 ]
机构
[1] Pharmacia Corp, Global Metab Invest Sci, Skokie, IL 60077 USA
关键词
Biacore; 3000; biosensor; enantiomers; immobilized albumins; affinity values; normalized responses;
D O I
10.1016/S0956-5663(02)00139-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The use of biosensors for monitoring real time interactions between biomolecules and drug compounds has a lot of advantages over presently existing detection methods, the major ones being the elimination of radio labels and rapid screening. We can also obtain information about the kinetic parameters and these values may serve as useful indicators towards subtle differences in the binding strength and characteristics of closely related drug compounds and enantiomers. The Biacore 3000 biosensor based on the Surface Plasmon Resonance (SPR) technology was used to assess the albumin protein binding differences between two enantiomers of a drug compound. Normalized responses (NRU) and affinity constants (K-D) were readily calculated. Statistical parameters like mean normalized responses, %CV values were determined to make the technique robust. The %CV values obtained were within the preset limits of less than or equal to25% (FDA limits for drug development and method validation protocols) for the binding interactions for majority of the concentrations studied. For example, the %CV values for the normalized responses for the binding of the control drug warfarin to human albumin ranged from 7.9 to 24.3%. The method gave reproducible results, and the results indicated slight differences in binding patterns of the enantiomers to human and rat albumin. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:399 / 404
页数:6
相关论文
共 14 条
[1]  
Al-Dirbashi OY, 2000, BIOMED CHROMATOGR, V14, P293, DOI 10.1002/1099-0801(200008)14:5<293::AID-BMC2>3.0.CO
[2]  
2-K
[3]   Direct thin layer chromatography enantioresolution of some basic DL-amino acids using a pharmaceutical industry waste as chiral impregnating reagent [J].
Bhushan, R ;
Martens, J ;
Thiongo, GT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 21 (06) :1143-1147
[4]   Enantiomer separation of drugs by capillary electromigration techniques [J].
Blaschke, G ;
Chankvetadze, B .
JOURNAL OF CHROMATOGRAPHY A, 2000, 875 (1-2) :3-25
[5]   Enantioselective sensor based on microgravimetric quartz crystal microbalance with molecularly imprinted polymer film [J].
Cao, L ;
Zhou, XC ;
Li, SFY .
ANALYST, 2001, 126 (02) :184-188
[6]   Stereoselective determination of cisapride, a prokinetic agent, in human plasma by chiral high-performance liquid chromatography with ultraviolet detection: application to pharmacokinetic study [J].
Desta, Z ;
Soukhova, NV ;
Morocho, A ;
Park, J ;
Mahal, SK ;
Flockhart, DA .
JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (02) :263-272
[7]   Stereoselective quantification of methadone and its major oxidative metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, in human urine using high-performance liquid chromatography [J].
Foster, DJR ;
Somogyi, AA ;
Bochner, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 744 (01) :165-176
[8]   Chiral discrimination using an immunosensor [J].
Hofstetter, O ;
Hofstetter, H ;
Wilchek, M ;
Schurig, V ;
Green, BS .
NATURE BIOTECHNOLOGY, 1999, 17 (04) :371-374
[9]   Determination of minute amounts of D-leucine in various brain regions of rat and mouse using column-switching high-performance liquid chromatography [J].
Inoue, T ;
Hamase, K ;
Morikawa, A ;
Zaitsu, K .
JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (01) :213-219
[10]   Determination of mandelic acid enantiomers in urine by gas chromatography and electron-capture or flame ionisation detection [J].
Kezic, S ;
Jakasa, I ;
Wenker, M .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (01) :39-46