An improved technique for breast cancer irradiation including the locoregional lymph nodes

被引:44
作者
Hurkmans, CW [1 ]
Saarnak, AE [1 ]
Pieters, BR [1 ]
Borger, JH [1 ]
Bruinvis, IAD [1 ]
机构
[1] Antoni Van Leeuwenhoek Huis, Netherlands Canc Inst, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 47卷 / 05期
关键词
breast irradiation; internal mammary lymph nodes; cardiac dose; 3D dose distribution; treatment technique;
D O I
10.1016/S0360-3016(00)00504-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To find an irradiation technique for locoregional irradiation of breast cancer patients which, compared with a standard technique, improves the dose distribution to the internal mammary-medial supraclavicular (IM-MS) lymph nodes, The improved technique is intended to minimize the lung dose and reduce the dose to the heart, Methods and Materials: The standard technique consists of an anterior mixed electron/photon IM-MS field. In the improved technique, an oblique electron and an oblique asymmetric photon field are combined to irradiate the BI IJ mph nodes. To irradiate the MS lymph nodes, a combination of an anterior electron and an anterior asymmetric photon field is used, For both the standard and the improved technique, tangential photon fields are used to irradiate the breast. Three-dimensional (3D) treatment planning was performed for 8 patients with various breast sizes for these two techniques, Dose-volume histograms (DVHs) and normal tissue complication probabilities (NTCPs were compared for both techniques, The field dimensions and energy of the standard technique were determined at simulation, whereas for the improved technique the fields were designed by CT-based treatment planning, Results: The dose in the breast planning target volume was essentially the same for both techniques. For the improved technique, combined with 3D localization information, an improvement in the IRI-MS planning target coverage is seen, The volume within the 95% isodose surface was on average 25% (range, 0-64%) and 74% (range, 43-90%) for the standard and improved technique, respectively. The heart generally receives less dose with the improved technique. However, sometimes a small but acceptable increase in lung dose is found, Conclusion: The improved technique, combined with localization information of the IM-MS lymph nodes, greatly improves the dose distribution in the planning target volume for a large group of patients without significantly increasing the dose to organs at risk. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1421 / 1429
页数:9
相关论文
共 44 条
[1]  
BARTELINK H, 1996, PHASE 3 RANDOMISED T
[2]   A SIMPLE TECHNIQUE FOR DETERMINING INTERNAL MAMMARY CHAIN DEPTH BY SONOGRAPHY [J].
BERNARDINO, ME ;
SPANOS, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (05) :671-673
[3]   MATCHING OF ADJACENT RADIATION BEAMS FOR ISOCENTRIC RADIOTHERAPY [J].
CASEBOW, MP .
BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (680) :735-740
[4]   QUALITY ASSURANCE USING PORTAL IMAGING - THE ACCURACY OF PATIENT POSITIONING IN IRRADIATION OF BREAST-CANCER [J].
CREUTZBERG, CL ;
ALTHOF, VGM ;
HUIZENGA, H ;
VISSER, AG ;
LEVENDAG, PC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :529-539
[5]  
CUZICK J, 1987, CANCER TREAT REP, V71, P15
[6]   CAUSE-SPECIFIC MORTALITY IN LONG-TERM SURVIVORS OF BREAST-CANCER WHO PARTICIPATED IN TRIALS OF RADIOTHERAPY [J].
CUZICK, J ;
STEWART, H ;
RUTQVIST, L ;
HOUGHTON, J ;
EDWARDS, R ;
REDMOND, C ;
PETO, R ;
BAUM, M ;
FISHER, B ;
HOST, H ;
LYTHGOE, J ;
RIBEIRO, G ;
SCHEURLEN, H .
JOURNAL OF CLINICAL ONCOLOGY, 1994, 12 (03) :447-453
[7]   8-YEAR RESULTS OF A RANDOMIZED CLINICAL-TRIAL COMPARING TOTAL MASTECTOMY AND LUMPECTOMY WITH OR WITHOUT IRRADIATION IN THE TREATMENT OF BREAST-CANCER [J].
FISHER, B ;
REDMOND, C ;
POISSON, R ;
MARGOLESE, R ;
WOLMARK, N ;
WICKERHAM, L ;
FISHER, E ;
DEUTSCH, M ;
CAPLAN, R ;
PILCH, Y ;
GLASS, A ;
SHIBATA, H ;
LERNER, H ;
TERZ, J ;
SIDOROVICH, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (13) :822-828
[8]  
FRAASS BA, 1987, P 9 INT C US COMP RA, P273
[9]  
FRAASS BA, 1987, P 9 INT C US COMP RA, P521
[10]   RADIATION-THERAPY OF STAGE-I BREAST-CANCER - ANALYSIS OF TREATMENT TECHNIQUE ACCURACY USING 3-DIMENSIONAL TREATMENT PLANNING TOOLS [J].
GAGLIARDI, G ;
LAX, I ;
RUTQVIST, LE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (02) :94-101