Semiautomated image registration for digital subtraction radiography

被引:24
作者
Byrd, V [1 ]
Mayfield-Donahoo, T [1 ]
Reddy, MS [1 ]
Jeffcoat, MK [1 ]
机构
[1] Univ Alabama Birmingham, Sch Dent 412, Dept Periodont, Adv Educ Program Periodont, Birmingham, AL 35294 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1998年 / 85卷 / 04期
关键词
D O I
10.1016/S1079-2104(98)90077-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of this study was to evaluate the semiautomatic alignment and correction of affine geometric discrepancies for digital subtraction radiography. Study design. Algorithms were tested in vitro to determine their ability to semiautomatically select reference points on a second image based on points selected on a first (reference) image. A preserved human mandible was imaged with and without bone-equivalent material chips at varying degrees of angulation. Each chip had a mass of less than 10 mg and was no more than 0.3 mm thick. High levels of specificity and sensitivity for chip detection were achieved with 6 degrees of angular discrepancy or less. The algorithms were then applied to radiographs from six human subjects through use of the bone-chip validation model. Results. Sensitivity was 89% and 100% for the three-point and four-point affine warp algorithms, respectively. Specificity for both algorithms was 100%. Conclusions. The data indicate that semiautomated alignment algorithms may enhance the efficacy of digital subtraction radiography while maintaining diagnostic efficacy in clinical trials.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 17 条
[1]  
DUNN SM, 1993, DENTOMAXILLOFAC RAD, V22, P76
[2]   DEVELOPMENT OF AUTOMATED REGISTRATION ALGORITHMS FOR SUBTRACTION RADIOGRAPHY [J].
ETTINGER, GJ ;
GORDON, GG ;
GOODSON, JM ;
SOCRANSKY, SS ;
WILLIAMS, R .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1994, 21 (08) :540-543
[3]   THE EFFECT OF INDEPENDENT FILM AND OBJECT ROTATION ON PROJECTIVE GEOMETRIC STANDARDIZATION OF DENTAL RADIOGRAPHS [J].
FISHER, E ;
VANDERSTELT, PF ;
OSTUNI, J ;
DUNN, SM .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (01) :5-12
[4]   A DIGITAL SUBTRACTION TECHNIQUE FOR DENTAL RADIOGRAPHY [J].
GRONDAHL, HG ;
GRONDAHL, K ;
WEBBER, RL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1983, 55 (01) :96-102
[5]   SUBTRACTION RADIOGRAPHY FOR THE DIAGNOSIS OF PERIODONTAL BONE-LESIONS [J].
GRONDAHL, HG ;
GRONDAHL, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1983, 55 (02) :208-213
[6]   EFFECT OF X-RAY-BEAM VERTICAL ANGULATION ON RADIOGRAPHIC ALVEOLAR CREST LEVEL MEASUREMENT [J].
HAUSMANN, E ;
ALLEN, K ;
CHRISTERSSON, L ;
GENCO, RJ .
JOURNAL OF PERIODONTAL RESEARCH, 1989, 24 (01) :8-19
[7]  
Jeffcoat M K, 1992, Clin Oral Implants Res, V3, P22, DOI 10.1034/j.1600-0501.1992.030104.x
[8]   A NEW METHOD FOR THE COMPARISON OF BONE LOSS MEASUREMENTS ON NON-STANDARDIZED RADIOGRAPHS [J].
JEFFCOAT, MK ;
JEFFCOAT, RL ;
WILLIAMS, RC .
JOURNAL OF PERIODONTAL RESEARCH, 1984, 19 (04) :434-440
[9]   Efficacy of quantitative digital subtraction radiography using radiographs exposed in a multicenter trial [J].
Jeffcoat, MK ;
Reddy, MS ;
Magnusson, I ;
Johnson, B ;
Meredith, MP ;
Cavanaugh, PF ;
Gerlach, RW .
JOURNAL OF PERIODONTAL RESEARCH, 1996, 31 (03) :157-160
[10]   EXTRAORAL CONTROL OF GEOMETRY FOR DIGITAL SUBTRACTION RADIOGRAPHY [J].
JEFFCOAT, MK ;
REDDY, MS ;
WEBBER, RL ;
WILLIAMS, RC ;
RUTTIMANN, JE .
JOURNAL OF PERIODONTAL RESEARCH, 1987, 22 (05) :396-402