A comparison of different strategies for the construction of amperometric enzyme biosensors using gold nanoparticle-modified electrodes

被引:161
作者
Mena, ML [1 ]
Yáñez-Sedeño, P [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
biosensors; gold nanoparticles; self-assembled monolayers;
D O I
10.1016/j.ab.2004.07.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A comparison of the analytical performances of several enzyme biosensor designs, based on the use of different tailored gold nanoparticle-modified electrode surfaces, is discussed. Glucose oxidase (GOx) and the redox mediator tetrathiafulvatene were coimmobilized in all cases by crosslinking with glutaraldehyde. The biosensor designs tested were based on the use of (i) colloidal gold (Au-coll) bound on cysteamine (Cyst) monolayers self-assembled on a gold disk electrode (AuE) and (ii) glassy carbon electrodes (GCEs) modified with electrodeposited gold nanoparticles (nAu). The results obtained with these designs were compared with those provided by a GOx/Cyst-AuE and a GOx/MPA-AuE. In the second case (ii), configurations based on direct immobilization of GOx on nAu (GOx/nAu-GCE) or on Cyst or MPA self-assembled monolayers (SAMs) previously bound on gold nanoparticles (GOx/Cyst-nAu-GCE or GOx/MPA-nAu-GCE, respectively) were compared. The analytical characteristics of glucose calibration plots and the kinetic parameters of the enzyme reaction were compared for all of the biosensors tested. The GOx/Au-coll-Cyst-AuE design showed a sensitivity for glucose determination higher than that achieved with GOx/Cyst-AuE and GOx/Au-coll-Cyst/Cyst-AuE and similar to that achieved with Gox/MPA-AuE. Moreover, the useful lifetime of one single GOx/Au-coll-Cyst-AuE was 28 days, remarkably longer than that of the other GOx biosensor designs. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 18 条
[1]   Colloid Au-enhanced DNA immobilization for the electrochemical detection of sequence-specific DNA [J].
Cai, H ;
Xu, C ;
He, PG ;
Fang, YZ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 510 (1-2) :78-85
[2]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[3]  
CARRALERO V, IN PRESS ANAL CHIM A
[4]   A new step to the mechanism of the enhancement effect of gold nanoparticles on glucose oxidase [J].
Chen, XY ;
Li, JR ;
Li, XC ;
Jiang, L .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1998, 245 (02) :352-355
[5]   Characteristics of the glucose oxidase at different surfaces [J].
Dong, XD ;
Lu, JT ;
Cha, CS .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01) :63-69
[6]   Characterization of n-alkanethiolate monolayers adsorbed to electrochemically deposited gold nanocrystals on glassy carbon electrodes [J].
Finot, MO ;
McDermott, MT .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 488 (02) :125-132
[7]   The application of alkanethiol self-assembled monolayers to enzyme electrodes [J].
Gooding, JJ ;
Hibbert, DB .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) :525-533
[8]   PREPARATION AND CHARACTERIZATION OF AU COLLOID MONOLAYERS [J].
GRABAR, KC ;
FREEMAN, RG ;
HOMMER, MB ;
NATAN, MJ .
ANALYTICAL CHEMISTRY, 1995, 67 (04) :735-743
[9]   Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid-cysteamine-modified gold electrode [J].
Gu, HY ;
Yu, AM ;
Chen, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 516 (1-2) :119-126
[10]   Adsorption characteristics of Fe(CN)36-/4 on Au colloids as monolayer films on cysteamine-modified gold electrode [J].
Hu, XY ;
Xiao, Y ;
Chen, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 466 (01) :26-30