Initial clinical results with the LifeSite® Hemodialysis Access System

被引:24
作者
Beathard, GA [1 ]
Posen, GA [1 ]
机构
[1] Ottawa Civic Hosp, Ottawa, ON K1Y 4E9, Canada
关键词
end-stage renal disease; chronic hemodialysis; vascular access; dialysis machine;
D O I
10.1111/j.1523-1755.2000.00397.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background The LifeSite(R) Hemodialysis Access System is a subcutaneous valve with an internal pinch clamp that is actuated with a standard 14-gauge dialysis needle, connected to a single lumen cannula placed in the central venous circulation for hemodialysis (HD). Methods. The LifeSite System (2 valves) was implanted in 23 patients with immediate dual-needle HD use. The cannulas were placed in either the jugular or the subclavian veins and were connected to the subcutaneous valves located in the upper chest area. Results. The mean duration of device survival for the LifeSite System was 6.8 +/- 0.97 months. During this period, the device achieved prescription HD blood flow rates averaging 384.7 +/- 78.5 mL/min with a venous pressure of 223.2 +/- 60.3 mm Hg. After 125 patient months, device removal because of infection was at a rate of 2.5 per 1000 days, and there were no devices removed because of poor flow. The average Kt/V for these patients was 1.51. Conclusion. This preliminary clinical study has validated the applicability of the LifeSite(R) Hemodialysis Access System as an access for HD. It is easily implanted and easily used, provides safe and effective dialysis, and is well accepted by patients. It should be especially useful as a bridge device to allow for maturation of a native fistula and will provide an alternative for long-term use in patients in whom a peripheral dialysis access is not feasible.
引用
收藏
页码:2221 / 2227
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 1997, AM J KIDNEY DIS S, V30, pS160
[2]  
BAKER LD, 1976, T AM SOC ART INT ORG, V22, P382
[3]  
Beathard GA, 1999, J AM SOC NEPHROL, V10, P1045
[4]  
GLANZ S, 1991, SEMIN DIALYSIS, V4, P157, DOI 10.1111/j.1525-139X.1991.tb00077.x
[5]   COMPARISON OF AUTOGENOUS FISTULA VERSUS EXPANDED POLYTETRAFLUOROETHYLENE GRAFT FISTULA FOR ANGIOACCESS IN HEMODIALYSIS [J].
KHERLAKIAN, GM ;
ROEDERSHEIMER, LR ;
ARBAUGH, JJ ;
NEWMARK, KJ ;
KING, LR .
AMERICAN JOURNAL OF SURGERY, 1986, 152 (02) :238-243
[6]  
Kinnaert P, 1990, ASAIO Trans, V36, P104, DOI 10.1097/00002480-199004000-00011
[7]   Outcome of tunneled hemodialysis catheters placed by radiologists [J].
Lund, GB ;
Trerotola, SO ;
Scheel, PF ;
Savader, SJ ;
Mitchell, SE ;
Venbrux, AC ;
Osterman, FA .
RADIOLOGY, 1996, 198 (02) :467-472
[8]   Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis [J].
Marr, KA ;
Sexton, DJ ;
Conlon, PJ ;
Corey, GR ;
Schwab, SJ ;
Kirkland, KB .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :275-+
[9]  
Mayers J D, 1992, ASAIO J, V38, P113, DOI 10.1097/00002480-199204000-00009
[10]   POLYTETRAFLUOROETHYLENE GRAFT-SURVIVAL IN HEMODIALYSIS [J].
MUNDA, R ;
FIRST, MR ;
ALEXANDER, JW ;
LINNEMANN, CC ;
FIDLER, JP ;
KITTUR, D .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1983, 249 (02) :219-222