Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI

被引:64
作者
Hamberg, LM
Boccalini, P
Stranjalis, G
Hunter, GJ
Huang, ZH
Halpern, E
Weisskoff, RM
Moskowitz, MA
Rosen, BR
机构
[1] MASSACHUSETTS GEN HOSP, DEPT RADIOL, MHG, NMR CTR, BOSTON, MA 02129 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA USA
[3] MASSACHUSETTS GEN HOSP, DEPT NEUROL, STROKE RES LAB, BOSTON, MA 02129 USA
[4] MASSACHUSETTS GEN HOSP, NEUROSURG SERV, BOSTON, MA USA
关键词
cerebral blood volume; magnetic resonance imaging; contrast agent; cerebral ischemia;
D O I
10.1002/mrm.1910350207
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated, The measurements were obtained during a 10-min period of occlusion and l-h period of reperfusion, Maximal hyperemic responses in gray matter, basal ganglia, and white matter (observed at 7, 7, and 5 min, respectively) were 1.9 +/- 0.5, 1.8 +/- 0.3, and 1.7 +/- 0.6 times greater than baseline CBV (mean +/- SEM), Thirty to forty minutes after onset of reperfusion, CBV returned to normal, Thereafter, it decreased below baseline, nearing the control level by 1 h after onset of reperfusion, Steady state susceptibility-contrast MRI permits continuous, in vivo mapping of alterations in CBV.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 26 条
[1]   FUNCTIONAL CEREBRAL IMAGING BY SUSCEPTIBILITY-CONTRAST NMR [J].
BELLIVEAU, JW ;
ROSEN, BR ;
KANTOR, HL ;
RZEDZIAN, RR ;
KENNEDY, DN ;
MCKINSTRY, RC ;
VEVEA, JM ;
COHEN, MS ;
PYKETT, IL ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :538-546
[2]   MR CONTRAST DUE TO MICROSCOPICALLY HETEROGENEOUS MAGNETIC-SUSCEPTIBILITY - NUMERICAL SIMULATIONS AND APPLICATIONS TO CEREBRAL PHYSIOLOGY [J].
FISEL, CR ;
ACKERMAN, JL ;
BUXTON, RB ;
GARRIDO, L ;
BELLIVEAU, JW ;
ROSEN, BR ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :336-347
[3]  
GROMAN EV, 1989, Patent No. 4827945
[4]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[5]   MEASUREMENT OF CEREBROVASCULAR CHANGES IN CATS AFTER TRANSIENT ISCHEMIA USING DYNAMIC MAGNETIC-RESONANCE-IMAGING [J].
HAMBERG, LM ;
MACFARLANE, R ;
TASDEMIROGLU, E ;
BOCCALINI, P ;
HUNTER, GJ ;
BELLIVEAU, JW ;
MOSKOWITZ, MA ;
ROSEN, BR .
STROKE, 1993, 24 (03) :444-451
[6]   MEASUREMENT OF REGIONAL BLOOD OXYGENATION AND CEREBRAL HEMODYNAMICS [J].
HOPPEL, BE ;
WEISSKOFF, RM ;
THULBORN, KR ;
MOORE, JB ;
KWONG, KK ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (06) :715-723
[7]   INTRAVASCULAR SUSCEPTIBILITY CONTRAST MECHANISMS IN TISSUES [J].
KENNAN, RP ;
ZHONG, JH ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :9-21
[8]   LOCAL CEREBRAL BLOOD-VOLUME DETERMINED BY 3-DIMENSIONAL RECONSTRUCTION OF RADIONUCLIDE SCAN DATA [J].
KUHL, DE ;
REIVICH, M ;
ALAVI, A ;
NYARY, I ;
STAUM, MM .
CIRCULATION RESEARCH, 1975, 36 (05) :610-619
[9]   HYPERCARBIA-INDUCED CHANGES IN CEREBRAL BLOOD-VOLUME IN THE CAT - A H-1 MRI AND INTRAVASCULAR CONTRAST AGENT STUDY [J].
MOSELEY, ME ;
CHEW, WM ;
WHITE, DL ;
KUCHARCZYK, J ;
LITT, L ;
DERUGIN, N ;
DUPON, J ;
BRASCH, RC ;
NORMAN, D .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :21-30
[10]   POSTOCCLUSIVE CEREBRAL HYPEREMIA IS MARKEDLY ATTENUATED BY CHRONIC TRIGEMINAL GANGLIONECTOMY [J].
MOSKOWITZ, MA ;
SAKAS, DE ;
WEI, EP ;
KANO, M ;
BUZZI, MG ;
OGILVY, C ;
KONTOS, HA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (05) :H1736-H1739