Turn geometry for minimizing band broadening in microfabricated capillary electrophoresis channels

被引:159
作者
Paegel, BM [1 ]
Hutt, LD [1 ]
Simpson, PC [1 ]
Mathies, RA [1 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
关键词
D O I
10.1021/ac000054r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Turns in microfabricated capillary electrophoresis channels generally result in degraded separation quality. To circumvent this limitation, channels were constructed with different types of turns to determine the design that minimizes turn-induced band broadening In particular, tapered turns were created by narrowing the separation channel width before the start of a turn and widening the channel after the turn is complete. The radius of curvature of the turn, the length over which the channel is tapered, and the degree of tapering were explored. The column efficiencies were determined by examining the resolution of the 271/281 base pair doublet in the separation of a phi X174 HaeIII DNA sizing ladder. Tapered turns with the smallest radius of curvature (250 mu m), the shortest tapering length between the separation and turn widths (55 mu m), and the largest tapering ratio (4:1 separation channel width to turn channel width) produced the highest resolution separations. These results are discussed by comparison to theoretical predictions of the effect of tapers and turns on analyte band dispersion in capillary electrophoresis.
引用
收藏
页码:3030 / 3037
页数:8
相关论文
共 27 条
[1]   Dispersion sources for compact geometries on microchips [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3781-3789
[2]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[3]  
HARRISON DJ, 1993, ANAL CHIM ACTA, V283, P361
[4]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[5]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[6]   Channel thickness variations could degrade resolution in electrophoresis [J].
Holzwarth, G .
ELECTROPHORESIS, 1996, 17 (10) :1587-1589
[7]   EFFECTS OF INJECTION SCHEMES AND COLUMN GEOMETRY ON THE PERFORMANCE OF MICROCHIP ELECTROPHORESIS DEVICES [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
WARMACK, RJ ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1107-1113
[8]   CONTRIBUTION OF CAPILLARY COILING TO ZONE DISPERSION IN CAPILLARY ZONE ELECTROPHORESIS [J].
KASICKA, V ;
PRUSIK, Z ;
GAS, B ;
STEDRY, M .
ELECTROPHORESIS, 1995, 16 (11) :2034-2038
[9]   Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels [J].
Liu, SR ;
Shi, YN ;
Ja, WW ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :566-573
[10]   ANALYSIS OF RESOLUTION IN DNA SEQUENCING BY CAPILLARY GEL-ELECTROPHORESIS [J].
LUCKEY, JA ;
NORRIS, TB ;
SMITH, LM .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (12) :3067-3075