Voltage Dynamics of Current Control Time-Scale in a VSC-Connected Weak Grid

被引:180
作者
Zhao, Mingquan [1 ,2 ]
Yuan, Xiaoming [1 ,2 ]
Hu, Jiabing [1 ,2 ]
Yan, Yabing [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
基金
国家自然科学基金重大项目;
关键词
Current control; voltage dynamics; voltage feed forward (VFF); voltage source converter (VSC); weak grid; wind turbine generator (WTG); FREQUENCY;
D O I
10.1109/TPWRS.2015.2482605
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Voltage problems are challenging in modern power systems with a high penetration of renewables integrated via power electronics. This paper extends the transient time-scale classification to identify voltage dynamics in modern power systems. Voltage dynamics in the current control time-scale is firstly proposed and then the mechanism of terminal voltage change is elaborated. After that the significant influences of the voltage source converter (VSC), current control (CC) loop and voltage feed forward (VFF) on the voltage dynamics in the current control time-scale are discussed. The VSC current control loop provides positive damping on the terminal voltage, while the VFF scheme results in an additional loop that deteriorates terminal voltage dynamic performance and stability. In addition, a sensitivity analysis was carried out to investigate the influence of critical parameters on stability. Finally, simulation results of a current-controlled VSC attached to different strength of AC grids (including a weak grid) are presented to validate the phenomenon and the influencing factors of voltage dynamics in the current control time-scale.
引用
收藏
页码:2925 / 2937
页数:13
相关论文
共 32 条
[1]   Suppression of line voltage related distortion in current controlled grid connected inverters [J].
Abeyasekera, T ;
Johnson, CM ;
Atkinson, DJ ;
Armstrong, M .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1393-1401
[2]   THE CONTINUATION POWER FLOW - A TOOL FOR STEADY-STATE VOLTAGE STABILITY ANALYSIS [J].
AJJARAPU, V ;
CHRISTY, C .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (01) :416-423
[3]  
[Anonymous], MODELING GE WIND TUR
[4]  
[Anonymous], P 2003 IEEE C CONTR
[5]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[6]   A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) :542-550
[7]  
Cate E. G., 1984, IEEE POWER ENG REV, VPER-4, P39
[8]   Grid Impact of Voltage Control and Reactive Power Support by Wind Turbines Equipped With Direct-Drive Synchronous Machines [J].
De Rijcke, Simon ;
Ergun, Hakan ;
Van Hertem, Dirk ;
Driesen, Johan .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2012, 3 (04) :890-898
[9]   VOLTAGE STABILITY EVALUATION USING MODAL-ANALYSIS [J].
GAO, B ;
MORISON, GK ;
KUNDUR, P .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (04) :1529-1542
[10]   Analysis of subsynchronous torsional interaction with power electronic converters [J].
Harnefors, Lennart .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (01) :305-313