Characteristics of corona and silent discharges as influenced by geometry of the discharge reactor

被引:41
作者
Abdel-Salam, M [1 ]
Hashem, A
Yehia, A
Mizuno, A
Turky, A
Gabr, A
机构
[1] Assiut Univ, Dept Elect Engn, Assiut 71516, Egypt
[2] Assiut Univ, Dept Phys, Fac Sci, Assiut 71516, Egypt
[3] Toyohashi Univ Technol, Dept Ecol Engn, Toyohashi, Aichi 4418580, Japan
关键词
D O I
10.1088/0022-3727/36/3/306
中图分类号
O59 [应用物理学];
学科分类号
摘要
This paper is aimed at investigating how the characteristics of corona and silent discharges including ozone generation are influenced by geometry of the discharge reactor. The corona discharges have been generated in coaxial wire-cylinder and wire-duct reactors stressed by dc and ac voltages. The silent discharges have been generated in the same reactors in addition to tubular reactors under ac voltage after pasting a dielectric barrier on the ground electrode of the reactors. The reactors were fed by dry air flowing at atmospheric pressure and temperature. The pulse characteristics of silent discharges are compared with those of ac corona discharges. The current-voltage and the ozone generation characteristics of silent and ac discharges are recorded. These characteristics depend significantly on the geometry of the reactor irrespective of the discharge type.
引用
收藏
页码:252 / 260
页数:9
相关论文
共 17 条
[1]   Ozone generation as influenced by gas flow in corona reactors [J].
AbdelSalam, M ;
Mizuno, A ;
Shimizu, K .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (05) :864-870
[2]   COMPUTATION OF ION-FLOW FIELDS OF AC CORONATING WIRES BY CHARGE SIMULATION TECHNIQUES [J].
ABDELSALAM, M ;
SHAMLOUL, D .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (02) :352-361
[3]   Ozone generation by indoor, electrostatic air cleaners [J].
Boelter, KJ ;
Davidson, JH .
AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (06) :689-708
[4]   OZONE GENERATION IN POSITIVE CORONA ELECTROSTATIC PRECIPITATORS [J].
CASTLE, GSP ;
INCULET, II ;
BURGESS, KI .
IEEE TRANSACTIONS ON INDUSTRY AND GENERAL APPLICATIONS, 1969, IGA5 (04) :489-&
[5]   NONEQUILIBRIUM VOLUME PLASMA CHEMICAL-PROCESSING [J].
ELIASSON, B ;
KOGELSCHATZ, U .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1991, 19 (06) :1063-1077
[6]  
GOSHO Y, 1987, 5 INT S HV ENG BRAUS
[7]  
HASHEM A, 2002, P 14 C GAS DISCH THE, V2, P362
[8]  
KHALIFA M, 2000, CORONA DISCHARGE HIG
[9]  
Kogelschatz U., 1992, 10TH P INT C GAS DIS, V2, P972
[10]   Optimization of a corona wire-to-cylinder ozone generator. Comparison with economical criteria. Part 1: Oxygen. [J].
Monge, C ;
Peyrous, R ;
Held, B .
OZONE-SCIENCE & ENGINEERING, 1997, 19 (06) :533-547