Application of models for multivariate mixed outcomes to medical device trials: coronary artery stenting

被引:24
作者
O'Malley, AJ
Normand, SLT
Kuntz, RE
机构
[1] Harvard Univ, Sch Med, Dept Hlth Care Policy, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Med,Div Clin Biometr & Cardiovasc Dis, Boston, MA 02115 USA
[3] Harvard Univ, Sch Publ Hlth, Dept Biostat, Boston, MA 02115 USA
关键词
coronary artery stents; Bayesian hierarchical modelling; mixed outcomes; latent variable; deviance information criterion; pseudo-Bayes factor;
D O I
10.1002/sim.1337
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The approval process for some medical devices involves a single-arm trial in which the outcomes associated with the new device are compared to the expected outcomes associated with approved devices, the latter denoted the objective performance criterion (OPC). In this paper, models for multivariate mixed outcomes are applied to derive the OPC for a medical device to be used in clinical evaluations of the same type of device. We illustrate the techniques by determining the OPC for coronary artery stents, metal cages used to widen blocked coronary arteries in patients with coronary artery disease, using data from seven randomized trials of stents approved for use in the U.S.A. involving 5806 patients. The OPC is based on two 9-month endpoints: target lesion revascularization, a binary outcome, and proportion diameter stenosis, a continuous outcome. To account for the correlation between mixed outcomes we consider factorization of the likelihood into marginal and conditional components, or adoption of a latent variable model. Because the models have different structural forms, standard methods for model comparison (such as the AIC and BIC) cannot be used. We discuss how model identifiability and valid inference are achieved, and then adapt the deviance information criterion (DIC) and the pseudo-Bayes factor (PSBF) to select the best model. Nine months post-stenting, we find that the average posterior probability (standard deviation) of target lesion revascularization ranges from 0.086 (0.008) for non-diabetics with one diseased vessel to 0.163 (0.022) for diabetics with three diseased vessels. When considering proportion diameter stenosis, the corresponding posterior means are 0.375 (0.020) and 0.427 (0.030). The correlation coefficient of the components of the OPC lies in the range 0.042 to 0.116. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:313 / 336
页数:24
相关论文
共 42 条
[1]  
AGRESTI A, 1990, CATEGORICAL DATA ANA, P319
[2]  
[Anonymous], P C FUND QUEST STAT
[3]  
Arminger G, 1988, LATENT TRAIT LATENT, P51
[4]   Final results of a randomized trial comparing the NIR stent to the Palmaz-Schatz stent for narrowings in native coronary arteries [J].
Baim, DS ;
Cutlip, DE ;
O'Shaughnessy, CD ;
Hermiller, JB ;
Kereiakes, DJ ;
Giambartolomei, A ;
Katz, S ;
Lansky, AJ ;
Fitzpatrick, M ;
Popma, JJ ;
Ho, KKL ;
Leon, MB ;
Kuntz, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :152-156
[5]   Final results of a randomized trial comparing the MULTI-LINK stent with the Palmaz-Schatz stent for narrowings in native coronary arteries [J].
Baim, DS ;
Cutlip, DE ;
Midei, M ;
Linnemeier, TJ ;
Schreiber, T ;
Cox, D ;
Kereiakes, D ;
Popma, JJ ;
Robertson, L ;
Prince, R ;
Lansky, AJ ;
Ho, KKL ;
Kuntz, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :157-162
[6]  
BERGER J. O., 2013, Statistical Decision Theory and Bayesian Analysis, DOI [10.1007/978-1-4757-4286-2, DOI 10.1007/978-1-4757-4286-2]
[7]  
BEST NG, 1995, CONVERGENCE DIAGNOSI
[8]   BIVARIATE LATENT VARIABLE MODELS FOR CLUSTERED DISCRETE AND CONTINUOUS OUTCOMES [J].
CATALANO, PJ ;
RYAN, LM .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1992, 87 (419) :651-658
[9]  
COX DR, 1972, J ROY STAT SOC C-APP, V21, P113, DOI 10.2307/2346482
[10]  
COX DR, 1992, BIOMETRIKA, V79, P441, DOI 10.1093/biomet/79.3.441