Electroluminescence technique to evaluate the effect of impulse tests on high voltage cables

被引:6
作者
Bamji, SS [1 ]
Kaufhold, M [1 ]
Bulinski, AT [1 ]
机构
[1] Natl Res Council Canada, Ottawa, ON, Canada
关键词
D O I
10.1109/94.671931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
EL (electroluminescence) in XLPE (crosslinked polyethylene) subjected to impulses of various amplitudes, shapes and repetition rates has been investigated. Defects that could occur in the polymeric insulation of underground Hv cables were simulated by embedding semicon protrusions in XLPE to create highly divergent electric fields. Time resolved measurement of the EL pulses emitted during positive, negative or alternating polarity impulses has shown that the EL pulses are grouped into two distinct time periods between - which there is no EL activity. The EL emission probability increased with fall time of the impulse voltage but was independent of the impulse rise time. A study of electroluminescence characteristics from unaged and aged XLPE, subjected to a pair of positive and negative impulses, indicated that the charge trapped in the polymeric insulation during aging plays an important role during impulse application and could affect insulation failure.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 9 条