Haemodynamic evaluation of cerebral arteriovenous malformations by quantification of transit time using high speed digital subtraction angiography: basic considerations
被引:15
作者:
Matsumoto, K
论文数: 0引用数: 0
h-index: 0
机构:
Kyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, JapanKyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, Japan
Matsumoto, K
[1
]
Urano, M
论文数: 0引用数: 0
h-index: 0
机构:Kyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, Japan
Urano, M
Hirai, M
论文数: 0引用数: 0
h-index: 0
机构:Kyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, Japan
Hirai, M
Masaki, H
论文数: 0引用数: 0
h-index: 0
机构:Kyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, Japan
Masaki, H
Tenjin, H
论文数: 0引用数: 0
h-index: 0
机构:Kyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, Japan
Tenjin, H
Mineura, K
论文数: 0引用数: 0
h-index: 0
机构:Kyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, Japan
Mineura, K
机构:
[1] Kyoto Prefectural Univ Med, Dept Neurosurg, Kamigyo Ku, Kyoto 6020841, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, Kamigyo Ku, Kyoto 6020841, Japan
cerebral arteriovenous malformations;
haemorrhage;
haemodynamics;
mean transit time;
D O I:
10.1054/jocn.2000.0709
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
It is important to evaluate the haemodynamics of cerebral arteriovenous malformations (AVMs) in order to predict and avoid complications following surgical intervention. This study measured the transit time of each component of AVMs by high-speed digital subtraction angiography (DSA) to understand the haemodynamics and to evaluate which parameter is an appropriate indicator for the monitoring. Eleven cases of cerebral AVMs were studied. Haemodynamics were evaluated by analysis of tracer transit using DSA. Tracer transit parameters including transit time and peak time were calculated by application of gamma fitting to time density curve, and measured in the following compartments; feeding artery, nidus and draining vein. Significant correlations of tracer transit parameters were present among compartments. Although there was no significant correlation of nidus volume and tracer transit parameters, the peak time was shorter in haemorrhage cases than in non-haemorrhage cases. Measurements of tracer transit parameters by high-speed DSA may be a useful tool for characterising and monitoring the haemodynamics of AVMs following surgical intervention. (C) 2000 Harcourt Publishers Ltd.
机构:
ST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USAST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USA
LAWTON, MT
;
HAMILTON, MG
论文数: 0引用数: 0
h-index: 0
机构:
ST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USAST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USA
HAMILTON, MG
;
SPETZLER, RF
论文数: 0引用数: 0
h-index: 0
机构:
ST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USAST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USA
机构:
ST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USAST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USA
LAWTON, MT
;
HAMILTON, MG
论文数: 0引用数: 0
h-index: 0
机构:
ST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USAST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USA
HAMILTON, MG
;
SPETZLER, RF
论文数: 0引用数: 0
h-index: 0
机构:
ST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USAST JOSEPHS HOSP, BARROW NEUROL INST, DIV NEUROL SURG, EDITORIAL OFF, PHOENIX, AZ 85013 USA