Accelerated partial breast irradiation using 3D conformal radiation therapy (3D-CRT)

被引:233
作者
Baglan, KL [1 ]
Sharpe, MB [1 ]
Jaffray, D [1 ]
Frazier, RC [1 ]
Fayad, J [1 ]
Kestin, LL [1 ]
Remouchamps, V [1 ]
Martinez, AA [1 ]
Wong, J [1 ]
Vicini, FA [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 02期
关键词
breast cancer; breast-conserving therapy; radiation therapy; brachytherapy;
D O I
10.1016/S0360-3016(02)03811-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We present a novel three-dimensional conformal radiation therapy (3D-CRT) technique to treat the lumpectomy cavity, plus a 1.5-cm margin, in patients with early-stage breast cancer and study its clinical feasibility. Methods and Materials: A 3D-CRT technique for partial-breast irradiation was developed using archived CT scans from 7 patients who underwent an active breathing control study. The clinical feasibility of this technique was then assessed in 9 patients who were prospectively enrolled on an Investigational Review Board-approved protocol of partial-breast irradiation. The prescribed dose was 34 Gy in 5 patients and 38.5 Gy in 4 patients, delivered in 10 fractions twice daily over 5 consecutive days. The impact of both breathing motion and patient setup uncertainty on clinical target volume (CTV) coverage was studied, and an appropriate CTV-to-PTV (planning target volume) margin was calculated. Results: By adding a CTV-to-PTV "breathing-only" margin of 5 mm, 98%-100% of the CTV remained covered by the 95% isodose surface at the extremes of normal inhalation and normal exhalation. The "total" CTV-to-PTV margin employed to accommodate organ motion and setup error (10 mm) was found to be sufficient to accommodate the observed uncertainty in the delivery precision. Patient tolerance was excellent, and acute toxicity was minimal. No skin changes were noted during treatment, and at the initial 4-8-week follow-up visit, only mild localized hyperpigmentation and/or erythema was observed. No instances of symptomatic radiation pneumonitis have occurred. Conclusions: Accelerated partial-breast irradiation using 3D-CRT is technically feasible, and acute toxicity to date has been minimal. A CTV-to-PTV margin of 10 mm seems to provide coverage for most patients. However, more patients and additional studies will be needed to validate the accuracy of this margin, and longer follow-up will be needed to assess acute and chronic toxicity, tumor control, and cosmetic results. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:302 / 311
页数:10
相关论文
共 67 条
[1]   Respiration-induced motion of the kidneys in whole abdominal radiotherapy: Implications for treatment planning and late toxicity [J].
Ahmad, NR ;
Huq, MS ;
Corn, BW .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (01) :87-90
[2]  
Back M F, 2000, Australas Radiol, V44, P60, DOI 10.1046/j.1440-1673.2000.00773.x
[3]   The use of high-dose-rate brachytherapy alone after lumpectomy in patients with early-stage breast cancer treated with breast-conserving therapy [J].
Baglan, KL ;
Martinez, AA ;
Frazier, RC ;
Kini, VR ;
Kestin, LL ;
Chen, PY ;
Edmundson, G ;
Mele, E ;
Jaffray, D ;
Vicini, FA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (04) :1003-1011
[4]   Variability of the location of internal mammary vessels and glandular breast tissue in breast cancer patients undergoing routine CT-based treatment planning [J].
Bentel, G ;
Marks, LB ;
Hardenbergh, P ;
Prosnitz, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1017-1025
[5]  
BILCHERTTOFT M, 1992, J NATL CANC I MONOGR, V11, P19
[6]  
Cionini L, 1993, LYON CHIR, V89, P128
[7]   Randomized clinical trial of breast irradiation following lumpectomy and axillary dissection for node-negative breast cancer: An update [J].
Clark, RM ;
Whelan, T ;
Levine, M ;
Roberts, R ;
Willan, A ;
McCulloch, P ;
Lipa, M ;
Wilkinson, RH ;
Mahoney, LJ .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1996, 88 (22) :1659-1664
[8]   RANDOMIZED CLINICAL-TRIAL TO ASSESS THE EFFECTIVENESS OF BREAST IRRADIATION FOLLOWING LUMPECTOMY AND AXILLARY DISSECTION FOR NODE-NEGATIVE BREAST-CANCER [J].
CLARK, RM ;
MCCULLOCH, PB ;
LEVINE, MN ;
LIPA, M ;
WILKINSON, RH ;
MAHONEY, LJ ;
BASRUR, VR ;
NAIR, BD ;
MCDERMOT, RS ;
WONG, CS ;
CORBETT, PJ .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1992, 84 (09) :683-689
[9]  
CLARKE DH, 1994, HIGH DOSE RATE BRACH, P321
[10]   ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN [J].
DAVIES, SC ;
HILL, AL ;
HOLMES, RB ;
HALLIWELL, M ;
JACKSON, PC .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) :1096-1102