Applications of a versatile sol-gel derived renewable electrode for capillary electrophoresis

被引:14
作者
Hua, L [1 ]
Tan, SN [1 ]
机构
[1] Nanyang Technol Univ, Div Chem, Sch Sci, Singapore 259756, Singapore
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 367卷 / 08期
关键词
D O I
10.1007/s002160000477
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new electrode has been developed and applied for amperometric detection in capillary electrophoresis (CE), comprised of carbon sol-gel composite material. The versatility of the sol-gel technique permits the flexible configuration of the electrode. The performance of such a sol-gel carbon composite electrode (CCE) is first evaluated in a typical CE application for the detection of purine-based compounds, Application of the CCE is also demonstrated for the detection of phenolic compounds in a micellar system. Separation resolution for non-ionic phenolic compounds can significantly be enhanced by introducing sodium dodecyl sulfate (SDS) at a concentration above its critical micelle concentration (cmc) to the buffer. Another design of the CCE incorporating the electrocatalyst Cu2O is employed for the analysis of sugars and organic acids based on dynamic modification with cetyltrimethylammonium bromide (CTAB). It has been found that the pl presence of surfactant ill the separation buffer does not adversely influence the electrochemical detection using a sol-gel derived carbon electrode.
引用
收藏
页码:697 / 700
页数:4
相关论文
共 21 条
[1]   DETERMINATION OF CARBOHYDRATES BY CAPILLARY ZONE ELECTROPHORESIS WITH AMPEROMETRIC DETECTION AT A COPPER MICROELECTRODE [J].
COLON, LA ;
DADOO, R ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :476-481
[2]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[3]   Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection [J].
Fermier, AM ;
Gostkowski, ML ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1661-1664
[4]   Simultaneous determination of sugars and organic acids by co-electroosmotic capillary electrophoresis with amperometric detection at a disk-shaped copper electrode [J].
Fu, CG ;
Song, LN ;
Fang, YZ .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :81-87
[5]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR WEIGHT CARBOXYLIC-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS CONDUCTIVITY DETECTION [J].
HUANG, XH ;
LUCKEY, JA ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :766-770
[6]   DETERMINATION OF SUGARS BY CAPILLARY ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION USING CUPROUS-OXIDE MODIFIED ELECTRODES [J].
HUANG, XJ ;
KOK, WT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 707 (02) :335-342
[7]   DETERMINATION OF SUGARS BY LIQUID-CHROMATOGRAPHY AND AMPEROMETRIC DETECTION WITH A CUPROUS-OXIDE MODIFIED ELECTRODE [J].
HUANG, XJ ;
POT, JJ ;
KOK, WT .
CHROMATOGRAPHIA, 1995, 40 (11-12) :684-689
[8]   ORGANICALLY MODIFIED SOL-GEL SENSORS [J].
LEV, O ;
TSIONSKY, M ;
RABINOVICH, L ;
GLEZER, V ;
SAMPATH, S ;
PANKRATOV, I ;
GUN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :A22-A30
[9]   Renewable silica sol-gel derived carbon composite based glucose biosensor [J].
Li, J ;
Chia, LS ;
Goh, NK ;
Tan, SN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 460 (1-2) :234-241
[10]   Sol-gel glass as a matrix for chemical and biochemical sensing [J].
Lin, J ;
Brown, CW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (04) :200-211