A study on biosafety of HAP ceramic prepared by SLA-3D printing technology directly

被引:68
作者
Chen, Qinghua [1 ,3 ,4 ]
Zou, Bin [1 ,3 ,4 ]
Lai, Qingguo [2 ,5 ]
Wang, Yang [2 ,5 ]
Xue, Runqi [2 ,5 ]
Xing, Hongyu [1 ,3 ,4 ]
Fu, Xiangsong [1 ,3 ,4 ]
Huang, Chuanzhen [1 ,3 ,4 ]
Yao, Peng [1 ,3 ,4 ]
机构
[1] Shandong Univ, Sch Mech Engn, Ctr Adv Jet Engn Technol CaJET, Jinan 250061, Shandong, Peoples R China
[2] Shandong Univ, Hosp 2, Dept Oral & Maxillofacial Surg, Jinan 250033, Shandong, Peoples R China
[3] Shandong Univ, Minist Educ, Key Lab High Efficiency & Clean Mech Mfg, Jinan, Shandong, Peoples R China
[4] Shandong Univ, Natl Demonstrat Ctr Expt Mech Engn Educ, Jinan, Shandong, Peoples R China
[5] Shandong Univ, Res Ctr 3D Printing Stomatol, Jinan, Shandong, Peoples R China
关键词
Hydroxyapatite; Stereolithography; Thermal properties; Cytotoxicity; Implant applications; Biosafety; MECHANICAL-PROPERTIES; POROUS HYDROXYAPATITE; COMPOSITE SCAFFOLDS; CALCIUM-PHOSPHATE; SURFACE QUALITY; PARAMETERS; STEREOLITHOGRAPHY; MICROSTRUCTURE; ARCHITECTURE; SUSPENSIONS;
D O I
10.1016/j.jmbbm.2019.06.031
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Hydroxyapatite powder was mixed into photosensitive resin to form complex shape scaffold using SLA-3D printing technology, and then the final entity was obtained successively by debinding and sintering. It is crucial to confirm whether the prepared hydroxyapatite scaffold have the toxic effects after our designed printing, debinding, and sintering processes because the photosensitive resin in the starting printing paste is poisonous to cells. To investigate these issues in details, thermogravimetric analysis (TG), differential scanning calorimetry (DSC), in vitro cytotoxicity test, and implantation pre-experiment in the rabbit parietal were performed, aiming to develop the SLA-3D prepared hydroxyapatite scaffold. Through thermal analysis, it was proved that photosensitive resin would be completely pyrolyzed at temperature ranging from 350 degrees C to 580 degrees C, corresponding to a secondary chemical reaction mechanism. Combined with cytotoxicity test results, it is unquestionable that the toxic substances would be totally decomposed after debinding process and a good biocompatible HAP samples could be obtained. The finally prepared HAP samples with micro-holes showed good biosafety in pre-experiment of the rabbit parietal implantation.
引用
收藏
页码:327 / 335
页数:9
相关论文
共 36 条
[1]
Achar B. N., 1969, P INT CLAY C, V1, P67
[2]
SYNTHESIS AND PROCESSING OF HYDROXYAPATITE CERAMIC TAPES WITH CONTROLLED POROSITY [J].
ARITA, IH ;
CASTANO, VM ;
WILKINSON, DS .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (01) :19-23
[3]
Ben-Nissan B., 2015, HYDROXYAPATITE HAP B, P21, DOI DOI 10.1016/B978-1-78242-033-0.00002-X
[4]
Stereolithography of structural complex ceramic parts [J].
Chartier, T ;
Chaput, C ;
Doreau, F ;
Loiseau, M .
JOURNAL OF MATERIALS SCIENCE, 2002, 37 (15) :3141-3147
[5]
Influence of irradiation parameters on the polymerization of ceramic reactive suspensions for stereolithography [J].
Chartier, Thierry ;
Dupas, Cyrielle ;
Geffroy, Pierre-Marie ;
Pateloup, Vincent ;
Colas, Maggy ;
Cornette, Julie ;
Guillemet-Fritsch, Sophie .
JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2017, 37 (15) :4431-4436
[6]
KINETIC PARAMETERS FROM THERMOGRAVIMETRIC DATA [J].
COATS, AW ;
REDFERN, JP .
NATURE, 1964, 201 (491) :68-&
[7]
COSTANTINO PD, 1991, ARCH OTOLARYNGOL, V117, P379
[8]
Doi Y, 1999, J BIOMED MATER RES, V47, P424, DOI 10.1002/(SICI)1097-4636(19991205)47:3<424::AID-JBM19>3.0.CO
[9]
2-0
[10]
3D PRINTING Additive manufacturing of polymer-derived ceramics [J].
Eckel, Zak C. ;
Zhou, Chaoyin ;
Martin, John H. ;
Jacobsen, Alan J. ;
Carter, William B. ;
Schaedler, Tobias A. .
SCIENCE, 2016, 351 (6268) :58-62