Flow velocity of central retinal artery and retrobulbar vessels during cardiovascular operations

被引:26
作者
Orihashi, K [1 ]
Matsuura, Y [1 ]
Sueda, T [1 ]
Shikata, H [1 ]
Morita, S [1 ]
Hirai, S [1 ]
Sueshiro, M [1 ]
Okada, K [1 ]
机构
[1] Hiroshima Univ, Sch Med, Dept Surg 1, Minami Ku, Hiroshima 734, Japan
关键词
D O I
10.1016/S0022-5223(97)70023-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Both blood how monitoring and pressure monitoring are necessary to avoid inadequate cerebral perfusion during cardiovascular operations. Inasmuch as transcranial Doppler ultrasonography does not provide a consistently good signal, especially during cardiopulmonary bypass, we examined the blood flow through the central retinal artery, which has proved to reflect an obstruction of the carotid artery. Method: Twenty-eight consecutive cases were examined with a 5 or 7.5 MHz conventional echocardiographic probe. Correlation between the maximal velocity at the central retinal artery and systolic blood pressure was examined. The blood flow of the central retinal artery and retrobulbar vessels was examined during selective or retrograde cerebral perfusion or intraaortic balloon pumping. Results: Blood flow could be clearly visualized but disappeared below a certain pressure in every case. With data from 478 measuring points, systolic blood pressure correlated with maximal velocity (r = 0.6902, p < 0.0001). The blood pressure-axis intercept, known as "critical closing pressure," was 35.8 +/- 14.8 mm Hg, varying among individuals and bilateral eyes. Pulsatility index increased after cardiopulmonary bypass (1.095 +/- 0.245 to 1.525 +/- 0.268, p < 0.0001). Patency of the circle of Willis was confirmed by the blood how during anastomosis of the ipsilateral artery. During retrograde cerebral perfusion, blood flow was detectable at the retrobulbar vessels. During intraaortic balloon pumping, the central retinal artery flow was augmented on inflation of the balloon. Conclusion: Orbital vessel monitoring provides the critical closing pressure of the central retinal artery and confirms patency of the circle of Willis. The eye can be "an acoustic window" into intracranial blood flow during cardiovascular surgery.
引用
收藏
页码:1081 / 1087
页数:7
相关论文
共 15 条
[1]  
[Anonymous], 1992, Transcranial Doppler
[2]   COLOR DOPPLER IMAGING OF THE EYE - NORMAL RANGES, REPRODUCIBILITY, AND OBSERVER VARIATION [J].
BAXTER, GM ;
WILLIAMSON, TH .
JOURNAL OF ULTRASOUND IN MEDICINE, 1995, 14 (02) :91-96
[3]  
CROUGHWELL N, 1992, J THORAC CARDIOV SUR, V103, P549
[4]  
DENNIS KJ, 1995, J ULTRAS MED, V14, P463
[5]   ARTERIAL ASSESSMENT BY DOPPLER-SHIFT ULTRASOUND [J].
GOSLING, RG ;
KING, DH .
PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1974, 67 (06) :447-449
[6]   SELECTIVE CEREBRAL PERFUSION DURING OPERATION FOR ANEURYSMS OF THE AORTIC-ARCH - A REASSESSMENT [J].
KAZUI, T ;
INOUE, N ;
YAMADA, O ;
KOMATSU, S .
ANNALS OF THORACIC SURGERY, 1992, 53 (01) :109-114
[7]  
LIEB WE, 1991, OPHTHALMOLOGY, V98, P548
[8]  
LINDEGAARD KF, 1992, TRANSCRANIAL DOPPLER, P67
[9]   The relationship between cerebral blood flow and transcranial Doppler blood flow velocity during hypothermic cardiopulmonary bypass in adults [J].
Nuttall, GA ;
Cook, DJ ;
Fulgham, JR ;
Oliver, WC ;
Proper, JA .
ANESTHESIA AND ANALGESIA, 1996, 82 (06) :1146-1151
[10]   CAROTID ARTERIES IN CENTRAL RETINAL VESSEL OCCLUSION AS ASSESSED BY DOPPLER ULTRASOUND [J].
PETERNEL, P ;
KEBER, D ;
VIDECNIK, V .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (11) :880-883