Pattern recognition techniques screening for drugs of abuse with gas chromatography-Fourier transform infrared spectroscopy

被引:15
作者
Praisler, M
Dirinck, I
Van Bocxlaer, J
De Leenheer, A
Massart, DL
机构
[1] State Univ Ghent, Fac Farmaceut Wetenschappen, Lab Med Biochem & Toxicol, B-9000 Ghent, Belgium
[2] Univ Galati, Dept Phys, Galati 6200, Romania
[3] Free Univ Brussels, Lab Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
关键词
GC-FTIR; drugs of abuse; pattern recognition; PCA; SIMCA;
D O I
10.1016/S0039-9140(00)00460-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As many drugs of abuse are relatively volatile substances, gas chromatography-mass spectrometry (GC-MS), and more recently gas chromatography-Fourier transform infrared spectroscopy (GC-FTIR) became the most powerful techniques applied for their identification. We are presenting a combination of pattern recognition techniques discriminating illicit amphetamines according to the substitution pattern associated with the psychotropic activity (stimulants and hallucinogens) for which they are abused, and with the corresponding level of health hazard. As we determined, GC-FTIR provides the best selectivity in identifying the structural features associated with the full constellation of pharmacological effects of amphetamines. The toxicological questions to be answered and the spectroscopic features enabling the screening based on soft independent modeling of class analogy (SIMCA) are discussed. The accuracy, sensitivity and selectivity of the system recommend its use for automating the investigations of illicit drugs for epidemiological, clinical, administrative and forensic purposes. As opposed to the traditional tests screening for drugs of abuse, the system may also be applied as a broad-spectrum screening test. The extent to which the output of a query for amphetamines may be used for assessing the class identity of a negative (i.e. other hallucinogens or stimulants, sympathomimetic amines, narcotics and precursors) was determined by a systematic principal component analysis (PCA). The basic information is summarized in tables according to the category or class of compounds found suitable for screening. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:177 / 193
页数:17
相关论文
共 11 条
[1]   Application of gas chromatography Fourier transform infrared spectrometry to the analysis of amphetamine analogues [J].
Dirinck, I ;
Meyer, E ;
Van Bocxlaer, J ;
Lambert, W ;
De Leenheer, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) :155-159
[2]   Derivation of substructures from infrared band shapes by fuzzy logic and partial cross correlation functions [J].
Ehrentreich, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (01) :56-60
[3]   EXPERT SYSTEM BASED ON PRINCIPAL COMPONENTS-ANALYSIS FOR THE IDENTIFICATION OF MOLECULAR-STRUCTURES FROM VAPOR-PHASE INFRARED-SPECTRA .2. IDENTIFICATION OF CARBONYL-CONTAINING FUNCTIONALITIES [J].
HASENOEHRL, EJ ;
PERKINS, JH ;
GRIFFITHS, PR .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :656-663
[4]   RAPID FUNCTIONAL-GROUP CHARACTERIZATION OF GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED-SPECTRA BY A PRINCIPAL COMPONENTS-ANALYSIS BASED EXPERT SYSTEM [J].
HASENOEHRL, EJ ;
PERKINS, JH ;
GRIFFITHS, PR .
ANALYTICAL CHEMISTRY, 1992, 64 (07) :705-710
[5]   FEASIBILITY OF USING GC FT-IR FOR DRUG ANALYSIS IN THE FORENSIC TOXICOLOGY LABORATORY [J].
KALASINSKY, KS ;
LEVINE, B ;
SMITH, ML .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (05) :332-336
[6]   DETECTION OF AMPHETAMINE AND METHAMPHETAMINE IN URINE BY GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED (GC/FTIR) SPECTROSCOPY [J].
KALASINSKY, KS ;
LEVINE, B ;
SMITH, ML ;
MAGLUILO, J ;
SCHAEFER, T .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (06) :359-364
[7]   FORENSIC DRUG ANALYSIS BY GC/FT-IR [J].
KEMPFERT, K .
APPLIED SPECTROSCOPY, 1988, 42 (05) :845-849
[8]   PATTERN-RECOGNITION CLASSIFICATION AND IDENTIFICATION OF TRACE ORGANIC POLLUTANTS IN AMBIENT AIR FROM MASS-SPECTRA [J].
SCOTT, DR ;
DUNN, WJ ;
EMERY, SL .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03) :281-283
[9]   PATTERN-RECOGNITION BY MEANS OF DISJOINT PRINCIPAL COMPONENTS MODELS [J].
WOLD, S .
PATTERN RECOGNITION, 1976, 8 (03) :127-139
[10]   PRINCIPAL COMPONENT ANALYSIS [J].
WOLD, S ;
ESBENSEN, K ;
GELADI, P .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1987, 2 (1-3) :37-52