Dual-axis tomography: An approach with alignment methods that preserve resolution

被引:816
作者
Mastronarde, DN [1 ]
机构
[1] Univ Colorado, Dept Mol Cellular & Dev Biol, Lab 3 Dimens Fine Struct, Boulder, CO 80309 USA
关键词
double-tilt; dual-axis; electron tomography; distortion correction; high voltage electron microscope;
D O I
10.1006/jsbi.1997.3919
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Tomographic reconstructions of biological specimens are now routinely being generated in our high voltage electron microscope by tilting the specimen around two orthogonal axes. Separate tomograms are computed from each tilt series. The two tomograms are aligned to each other with general 3-D linear transformations that can correct for distortions between the two tomograms, thus preserving the inherent resolution of the reconstruction throughout its volume. The 3-D Fourier transforms of the two tomograms are then selectively combined to achieve a single tomogram. Unlike a single-axis tomogram, a dual-axis tomogram shows good resolution for extended features at any orientation in the plane of the specimen; it also has improved resolution in the depth of the specimen. Calculations indicate that the improvements available from double tilting and from tilting to higher angles are largely additive. Actual and model data were used to assess whether varying the increment between tilted views in proportion to the cosine of the tilt angle would allow a reduction in the number of pictures required to achieve a given resolution of reconstruction. Analysis by Fourier sector correlation indicated that the variable tilt increment improved the reconstruction in some respects but degraded it in others. A varying tilt increment thus does not give an unqualified improvement, at least when using back-projection algorithms for the reconstruction. (C) 1997 Academic Press.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 20 条
[1]   INFORMATION RECOVERY IN MISSING ANGULAR DATA CASES - AN APPROACH BY THE CONVEX PROJECTIONS METHOD IN 3 DIMENSIONS [J].
CARAZO, JM ;
CARRASCOSA, JL .
JOURNAL OF MICROSCOPY-OXFORD, 1987, 145 :23-43
[2]  
CARAZO JM, 1992, ELECT TOMOGRAPHY, P91
[3]   RECONSTRUCTION OF 3 DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON MICROSCOPY [J].
CROWTHER, RA ;
DEROSIER, DJ ;
KLUG, A .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1530) :319-&
[4]   SPIDER - A MODULAR SOFTWARE SYSTEM FOR ELECTRON IMAGE-PROCESSING [J].
FRANK, J ;
SHIMKIN, B ;
DOWSE, H .
ULTRAMICROSCOPY, 1981, 6 (04) :343-357
[5]  
FRANK J, 1986, ADV TECHNIQUES BIOL, V3, P1
[6]  
Frank J., 1992, ELECT TOMOGRAPHY
[7]   RECONSTRUCTION OF A 3-DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON-MICROSCOPY .2. DIRECT METHODS [J].
GILBERT, PFC .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1972, 182 (1066) :89-+
[8]  
Hawkes P.W., 1992, The Electron Microscope as a Structure Projector in Electron Tomogaphy: Three-Dimensional Imaging with the Transmission Electron Microscope, P17
[9]   Computer visualization of three-dimensional image data using IMOD [J].
Kremer, JR ;
Mastronarde, DN ;
McIntosh, JR .
JOURNAL OF STRUCTURAL BIOLOGY, 1996, 116 (01) :71-76
[10]  
KREMER JR, 1990, P 12 INT C EL MICR, V3, P752