Survivorship and Clinical Outcomes of Custom Triflange Acetabular Components in Revision Total Hip Arthroplasty: A Systematic Review

被引:75
作者
De Martino, Ivan [1 ]
Strigelli, Vanni [1 ]
Cacciola, Giorgio [1 ]
Gu, Alex [1 ]
Bostrom, Mathias P. [1 ]
Sculco, Peter K. [1 ]
机构
[1] Hosp Special Surg, Dept Orthopaed Surg, Stavros Niarchos Fdn, Complex Joint Reconstruct Ctr, 535 East 70th St, New York, NY 10021 USA
关键词
custom triflange; acetabular deficiency; survivorship; complication; revision total hip arthroplasty; dislocation; MANAGEMENT; RECONSTRUCTION; CUP; CLASSIFICATION; DEFECTS; IMPLANT; CAGE;
D O I
10.1016/j.arth.2019.05.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Several studies have evaluated the survivorship and clinical outcomes of custom triflange acetabular component (CTAC) usage in complex acetabular revision; however, there remains no consensus on the overall performance of this custom implant design. We therefore performed a systematic review of the literature in order to examine survivorship and complication rate of CTAC usage. Methods: A systematic review of the literature according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was performed. A comprehensive search of PubMed, MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews was conducted for English articles using various combinations of the keywords "custom triflange," "custom-made triflange," "acetabular triflange," "THA," "THR," "revision," "bone loss," "bone defect," and "pelvic discontinuity." Results: In all, 17 articles met our inclusion criteria. A total of 579 CTACs were implanted. The all-cause revision-free survivorship was 82.7%. The overall complication rate was 29%. Dislocation and infection were the most common complications observed with an incidence of 11% and 6.2%, respectively. Nerve injuries following CTAC placement had an incidence of 3.8%. The incidence of CTAC aseptic loosening was 1.7%. Overall, patients had improved outcomes as documented by postoperative hip scores. Conclusion: Based on the current data, CTACs have a high complication rate but remain an efficacious treatment option in complex acetabular reconstructions. When dealing with patients with significant acetabular bone loss for revision total hip arthroplasty, surgeons should continue to consider CTACs as a viable option but educate patients as to the increased risk of postoperative complications and reoperations. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:2511 / 2518
页数:8
相关论文
共 34 条
[1]
Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss [J].
Abolghasemian, M. ;
Tangsataporn, S. ;
Sternheim, A. ;
Backstein, D. ;
Safir, O. ;
Gross, A. E. .
BONE & JOINT JOURNAL, 2013, 95B (02) :166-172
[2]
Management of Paprosky type three B acetabular defects by custom-made components: early results [J].
Aprato, Alessandro ;
Giachino, Matteo ;
Bedino, Paolo ;
Mellano, Danilo ;
Piana, Raimondo ;
Masse, Alessandro .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (01) :117-122
[3]
A Custom-made Acetabular Implant for Paprosky Type 3 Defects [J].
Baauw, Marieke ;
van Hellemondt, Gijs Gerard ;
Spruit, Maarten .
ORTHOPEDICS, 2017, 40 (01) :E195-E198
[4]
CURRENT CONSTRUCT OPTIONS FOR REVISION OF LARGE ACETABULAR DEFECTS A Systematic Review [J].
Baauw, Marieke ;
van Hooff, Miranda L. ;
Spruit, Maarten .
JBJS REVIEWS, 2016, 4 (11) :e2
[5]
Systematic review on outcomes of acetabular revisions with highly-porous metals [J].
Banerjee, Samik ;
Issa, Kimona ;
Kapadia, Bhaveen H. ;
Pivec, Robert ;
Khanuja, Harpal S. ;
Mont, Michael A. .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) :689-702
[6]
Outcomes of Custom Flange Acetabular Components in Revision Total Hip Arthroplasty and Predictors of Failure [J].
Barlow, Brian T. ;
Oi, Kathryn K. ;
Lee, Yuo-yu ;
Carli, Alberto V. ;
Choi, Daniel S. ;
Bostrom, Mathias P. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (05) :1057-1064
[7]
Loosening After Acetabular Revision: Comparison of Trabecular Metal and Reinforcement Rings. A Systematic Review [J].
Beckmann, Nicholas A. ;
Weiss, Stefan ;
Klotz, Matthias C. M. ;
Gondan, Matthias ;
Jaeger, Sebastian ;
Bitsch, Rudi G. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (01) :229-235
[8]
Are Custom Triflange Acetabular Components Effective for Reconstruction of Catastrophic Bone Loss? [J].
Berasi, Carl C. ;
Berend, Keith R. ;
Adams, Joanne B. ;
Ruh, Erin L. ;
Lombardi, Adolph V., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) :528-535
[9]
Berend ME, 2018, BONE JOINT J, V100B, P50, DOI [10.1302/0301-620X.10061.BJJ-2017-0362.R1, 10.1302/0301-620X.100B1.BJJ-2017-0362.R1]
[10]
REVISION ARTHROPLASTY USING AN ANTI-PROTRUSIO CAGE FOR MASSIVE ACETABULAR BONE DEFICIENCY [J].
BERRY, DJ ;
MULLER, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (05) :711-715