Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses

被引:20
作者
Hayashi, K
Hayashi, H
Oshika, T
Hayashi, F
机构
[1] Hayashi Eye Hosp, Hakata Ku, Fukuoka 812, Japan
[2] Fukuoka Univ, Sch Med, Dept Ophthalmol, Fukuoka 81401, Japan
[3] Univ Tokyo, Sch Med, Dept Ophthalmol, Tokyo 113, Japan
关键词
D O I
10.1016/S0886-3350(00)00435-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate irregular astigmatism after silicone, acrylic, and poly(methyl methacrylate) (PMMA) intraocular lens (IOL) implantation using Fourier analysis of videokeratography data. Methods: Two hundred forty eyes having phacoemulsification and IOL implantation were randomly assigned to 1 of 3 groups: 3.5 mm incision and silicone IOL, 4.1 mm incision and acrylic IOL, or 6.5 mm incision and PMMA IOL. All eyes had videokeratographic examinations preoperatively and 2, 4, and 10 days and 1 and 3 months postoperatively. The dioptric data of the central cornea were decomposed into spherical equivalent, regular astigmatism, and irregular astigmatism (decentration and higher-order irregularity) components using Fourier analysis. Results: Regular astigmatism in the PMMA group was greater than in the silicone and acrylic groups. Decentration in all 3 groups increased significantly postoperatively but virtually returned to preoperative levels by 10 days. No significant difference was observed among the 3 groups. Higher-order irregularity significantly increased after surgery in all 3 groups. The higher-order irregularity in the PMMA group persisted for up to 1 month, while that in the silicone and acrylic groups returned to preoperative levels by 4 days, resulting in significant differences between these groups 10 days and 1 month after IOL implantation. Conclusion: Irregular astigmatism, both the decentration and higher-order irregularity components, increased significantly after 3 types of scleral tunnel incisions for silicone, acrylic, or PMMA IOL implantation but returned to preoperative levels soon after surgery except for the higher order irregularity after PMMA IOL implantation. J Cataract Refract Surg 2000; 26:1510-1516 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:1510 / 1516
页数:7
相关论文
共 23 条
[1]   REDUCTION OF POSTOPERATIVE AGAINST-THE-RULE ASTIGMATISM BY LATERAL INCISION TECHNIQUE [J].
AXT, JC ;
MCCAFFERY, JM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (03) :380-386
[3]   EFFECT OF INCISION SIZE ON EARLY POSTOPERATIVE VISUAL REHABILITATION AFTER CATARACT-SURGERY AND INTRAOCULAR-LENS IMPLANTATION [J].
ELMAGHRABY, A ;
ANWAR, M ;
ELSAYYAD, F ;
MATHEEN, M ;
MARZOUKY, A ;
GAZAYERLI, E ;
SALAH, T ;
BALLEW, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (04) :494-498
[4]  
Ernest PH, 1990, SMALL INCISION CATAR, P103
[5]  
ERNEST PH, 1992, SUTURELESS CATARACT, P51
[6]   THE CORRELATION BETWEEN INCISION SIZE AND CORNEAL SHAPE CHANGES IN SUTURELESS CATARACT-SURGERY [J].
HAYASHI, K ;
HAYASHI, H ;
NAKAO, F ;
HAYASHI, F .
OPHTHALMOLOGY, 1995, 102 (04) :550-556
[7]   FOURIER-ANALYSIS OF VIDEO-KERATOGRAPHIC DATA - A TOOL FOR SEPARATION OF SPHERICAL, REGULAR ASTIGMATIC AND IRREGULAR ASTIGMATIC CORNEAL POWER COMPONENTS [J].
HJORTDAL, JO ;
ERDMANN, L ;
BEK, T .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1995, 15 (03) :171-185
[8]   Fourier analysis of corneal topography data after photorefractive keratectomy [J].
Keller, PR ;
McGhee, CNJ ;
Weed, KH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (11) :1447-1455
[9]   COMPARISON OF THE INDUCED ASTIGMATISM AFTER TEMPORAL CLEAR CORNEAL TUNNEL INCISIONS OF DIFFERENT SIZES [J].
KOHNEN, T ;
DICK, B ;
JACOBI, KW .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (04) :417-424
[10]   EFFECT OF CATARACT WOUND INCISION SIZE ON ACUTE CHANGES IN CORNEAL TOPOGRAPHY [J].
MARTIN, RG ;
SANDERS, DR ;
MILLER, JD ;
COX, CC ;
BALLEW, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 :170-177