Simple model of double adiabatic inversion (DAI) efficiency

被引:12
作者
Gach, HM
Dai, WY
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Dept Comp Sci, Pittsburgh, PA 15213 USA
关键词
arterial spin labeling; perfusion MRI; inversion efficiency;
D O I
10.1002/mrm.20240
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multislice continuous arterial spin labeling (CASL) using alternating single adiabatic inversion (SAI) and double adiabatic inversion (DAI) (ASD) suffers from control inefficiencies that reduce the perfusion signal-to-noise ratio (SNR). A simple analytic model for DAI efficiency (X) is presented, and compared with simulation and experimental data. The DAI efficiency (defined as the ratio of uninverted to equilibrium spins) depends primarily on the effective adiabaticity (beta') and the inversion time (both determined from the labeling RF field and gradient amplitudes, and flow velocities). In this study, X behaved like a damped oscillator, starting from 1 at beta' = 0 (no spin inversion), dropping to 0.5 at beta' = 0.5 (spin saturation), rising again to a peak at beta' similar to 3, and subsequently oscillating at higher beta'. The simple model matched the flow phantom data for beta' < 2, with an accuracy of better than 10%, but it diverged from the flow phantom data as the data oscillated at higher beta'. The relative inversion efficiencies of ASD and simultaneous proximal and distal irradiation (SPDI) were measured in 28 elderly volunteers. The ratio of CASL difference (control - label) signals measured in gray matter ( = 1.16 +/- 0.05), and the simple efficiency models ( = 1.13 +/- 0.02) had a correlation coefficient of 0.974. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 25 条
  • [1] Multisection cerebral blood flow MR imaging with continuous arterial spin labeling
    Alsop, DC
    Detre, JA
    [J]. RADIOLOGY, 1998, 208 (02) : 410 - 416
  • [2] Barth M, 1997, CELL MOL BIOL, V43, P783
  • [3] Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling
    Chalela, JA
    Alsop, DC
    Gonzalez-Atavales, JB
    Maldjian, JA
    Kasner, SE
    Detre, JA
    [J]. STROKE, 2000, 31 (03) : 680 - 687
  • [4] Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
    Detre, JA
    Alsop, DC
    Vives, LR
    Maccotta, L
    Teener, JW
    Raps, EC
    [J]. NEUROLOGY, 1998, 50 (03) : 633 - 641
  • [5] Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system
    Detre, JA
    Alsop, DC
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (02) : 115 - 124
  • [6] Quantitative analysis of adiabatic fast passage for steady laminar and turbulent flows
    Gach, HM
    Kam, AW
    Reid, ED
    Talagala, SL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) : 709 - 719
  • [7] GACH HM, 2002, P 10 ANN M ISMRM HON, P1071
  • [8] GACH HM, 2001, P 9 ANN M ISMRM GLAS, P1568
  • [9] Gonzalez-At JB, 2000, MAGNET RESON MED, V43, P739, DOI 10.1002/(SICI)1522-2594(200005)43:5<739::AID-MRM17>3.0.CO
  • [10] 2-2