A simple telemedicine system using a digital camera

被引:38
作者
Corr, P
Couper, I
Beningfield, SJ
Mars, M
机构
[1] Univ Natal, Dept Radiol, Pietermaritzburg, South Africa
[2] Univ Natal, Dept Physiol, Pietermaritzburg, South Africa
[3] Manguzi Hosp, KwaZulu Natal, South Africa
[4] Dept Family Med, Pretoria, South Africa
[5] Univ Cape Town, Dept Radiol, ZA-7925 Cape Town, South Africa
关键词
D O I
10.1258/1357633001935293
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Radiographs on a viewing box were photographed at a remote hospital in South Africa using a digital camera with a resolution of 1024 x 768 pixels at 24-bit colour depth. The resultant images were stored in JPEG format and transmitted as email attachments to be read on a PC monitor by radiologists in Durban and Cape Town. Twenty-seven images were received, of which 23 were of diagnostic quality (85%). The mean file size was 120 kByte. For quality control purposes, 100 chest radiographs were photographed at a base hospital and read by a radiologist blinded to the diagnosis. In this study 96 images were of diagnostic quality (96%) and the correct diagnosis was made in 90 cases (94%). Incorrect readings were made in six cases (6%): small pulmonary nodules (less than 1 cm in diameter) were missed in five cases and in one case early apical tuberculosis was missed. Digital camera technology permits simple, inexpensive telemedicine. Limited spatial resolution is a concern when reading chest images with small pulmonary nodules and infiltrates.
引用
收藏
页码:233 / 236
页数:4
相关论文
共 9 条
[1]   Training for telemedicine [J].
Blignault, I ;
Kennedy, C .
JOURNAL OF TELEMEDICINE AND TELECARE, 1999, 5 :112-114
[2]   The diagnostic performance of a PC-based teleradiology link [J].
Calder, LD ;
Maclean, JR ;
Bayliss, AP ;
Gilbert, FJ ;
Grant, AM .
CLINICAL RADIOLOGY, 1999, 54 (10) :659-664
[3]  
Corr P, 1998, S AFR MED J, V88, P48
[4]  
Furness PN, 1997, J PATHOL, V183, P253, DOI 10.1002/(SICI)1096-9896(199711)183:3<253::AID-PATH927>3.0.CO
[5]  
2-P
[6]  
Goldberg MA, 1996, RADIOL CLIN N AM, V34, P647
[7]   Telemedicine [J].
Murdoch, I .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (11) :1254-1256
[8]   Digital cameras: A rapid and inexpensive means of transferring angiographic images to referring clinicians [J].
Omary, RA ;
Salem, R ;
Wendt, G ;
McDermott, JC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (07) :994-995
[9]   Use of digital cameras for radiographs: how to get the best pictures [J].
Whitehouse, RW .
JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1999, 92 (04) :178-182