Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion

被引:98
作者
Yarnykh, VL [1 ]
Yuan, C [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
black-blood imaging; double inversion recovery; carotid artery; atherosclerosis; vessel wall;
D O I
10.1002/jmri.10278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a technique for time-efficient multislice double inversion-recovery (DIR) black-blood imaging and to test its applicability and limitations for high-resolution imaging of carotid arteries. Materials and Methods: A multislice DIR pulse sequence with fast spin-echo (FSE) readout was implemented on a 1.5T magnetic resonance (MR) scanner. The principle of the method is that a slice selective inversion in a DIR preparation reinverts an entire slice pack, and all slices are imaged within repetition time (TR). The number of slices acquired per TR (N) controls the inversion time (TI) to execute the readout for each slice at the zero-crossing point of blood. Multislice DIR images (TR/TE = 2500/9 msec) of carotid arteries were obtained with variable N = 2-8 from four subjects. The method was compared with the standard single-slice DIR and inflow saturation techniques. Results: Multislice DIR with N = 2-6 provided similar flow suppression in carotid arteries as single-slice DIR. At all N = 1-8, blood suppression by DIR was significantly better than by inflow saturation. An additional limitation of multislice DIR was saturation of the signal from stationary tissues that worsened visualization of the vessel wall at N greater than or equal to 6. Conclusion: Multislice DIR provides up to eight-fold improvement of time-efficiency relative to single-slice DIR and high-quality blood suppression.
引用
收藏
页码:478 / 483
页数:6
相关论文
共 13 条
[1]   CAROTID SONOGRAPHY [J].
CARROLL, BA .
RADIOLOGY, 1991, 178 (02) :303-313
[2]   EXTRACRANIAL CAROTID ARTERIES - EVALUATION WITH BLACK BLOOD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MATTLE, HP ;
WALLNER, B ;
BAJAKIAN, R ;
KLEEFIELD, J ;
KENT, C ;
SKILLMAN, JJ ;
MENDEL, JB ;
ATKINSON, DJ .
RADIOLOGY, 1990, 177 (01) :45-50
[3]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[4]   MAGNETIZATION TRANSFER EFFECTS IN MULTISLICE RARE SEQUENCES [J].
MELKI, PS ;
MULKERN, RV .
MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (01) :189-195
[5]   Improved efficiency in double-inversion fast spin-echo imaging [J].
Parker, DL ;
Goodrich, KC ;
Masiker, M ;
Tsuruda, JS ;
Katzman, GL .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :1017-1021
[6]  
Pettigrew RI, 1999, J MAGN RESON IMAGING, V10, P590, DOI 10.1002/(SICI)1522-2586(199911)10:5<590::AID-JMRI2>3.3.CO
[7]  
2-J
[8]   ''Black blood'' T2-weighted inversion-recovery MR imaging of the heart [J].
Simonetti, OP ;
Finn, JP ;
White, RD ;
Laub, G ;
Henry, DA .
RADIOLOGY, 1996, 199 (01) :49-57
[9]   Multislice double inversion pulse sequence for efficient black-blood MRI [J].
Song, HK ;
Wright, AC ;
Wolf, RL ;
Wehrli, FW .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :616-620
[10]  
SONG HK, 2002, P 10 ANN M ISMRM HON, P1566