A novel approach for distortion correction for X-ray image intensifiers

被引:28
作者
Soimu, D [1 ]
Badea, C [1 ]
Pallikarakis, N [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26500, Greece
关键词
X-ray image intensifier; distortion correction; three-dimensional reconstruction; digital tomosynthesis;
D O I
10.1016/S0895-6111(02)00055-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Applications of X-ray image intensifiers in medical imaging, include the use of fluoroscopic projection images to generate three-dimensional tomographic reconstructions. Unfortunately, the inherent distortions on the acquired projections deteriorate the quality of the reconstructed tomograms. Distortion correction can be performed using algorithms that can be classified as global or local according to the method used, both having specific advantages and disadvantages. In this work, a novel approach for distortion correction is proposed which, by combining both global and local correction methods allows good image quality in relatively acceptable time. Correction parameters were obtained using a calibration phantom specially designed for this purpose. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 13 条
[1]   Image quality in extended arc filtered digital tomosynthesis [J].
Badea, C ;
Kolitsi, Z ;
Pallikarakis, N .
ACTA RADIOLOGICA, 2001, 42 (02) :244-248
[2]   IMAGE INTENSIFIER DISTORTION CORRECTION [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1987, 14 (02) :249-252
[3]   CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[4]   Digital radiotherapy simulator [J].
Cho, PS ;
Lindsley, KL ;
Douglas, JG ;
Stelzer, KJ ;
Griffin, TW .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1998, 22 (01) :1-7
[5]   Computer-aided radiation therapy simulation: image intensifier spatial distortion correction for large field of view digital fluoroscopy [J].
Cosby, NS ;
Leszczynski, KW .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2265-2278
[6]   Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion [J].
Fahrig, R ;
Moreau, M ;
Holdsworth, DW .
MEDICAL PHYSICS, 1997, 24 (07) :1097-1106
[7]  
Forlani C, 2001, LECT NOTES COMPUT SC, V2074, P23
[8]   CALIBRATION AND CORRECTION OF SPATIAL DISTORTIONS IN 2D DETECTOR SYSTEMS [J].
HAMMERSLEY, AP ;
SVENSSON, SO ;
THOMPSON, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2) :312-321
[9]   Super-global distortion correction for a rotational C-arm x-ray image intensifier [J].
Liu, RR ;
Rudin, S ;
Bednarek, DR .
MEDICAL PHYSICS, 1999, 26 (09) :1802-1810
[10]  
OEMICHEA F, 1999, LITHISYR2204