Platelet deposition on stainless steel, spiral, and braided polylactide stents - A comparative study

被引:10
作者
Hietala, EM
Maasilta, P
Juuti, H
Nuutinen, JP
Harjula, ALJ
Salminen, US
Lassila, R
机构
[1] Univ Helsinki Hosp, Dept Surg, FIN-00029 Helsinki, Finland
[2] Univ Helsinki Hosp, Dept Med, Helsinki, Finland
[3] Univ Helsinki Hosp, Dept Hematol, Helsinki, Finland
[4] Inst Biomat, Tampere, Finland
关键词
stent; vascular; thrombosis; heparin; polylactide;
D O I
10.1160/TH04-02-0124
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Platelets play a key role in (sub)acute thrombotic occlusion after stenting. We examined the possible differences between biodegradable polylactide (PLA) and stainless steel (SS) stents in platelet attachment and morphology after whole blood perfusion. PLA stents of different configurations (spiral/braided) and polycaprolactone-polylactide (PCL-PLA)-coatings, or SS stents were implanted into a PVC tube (circle divide 3.2 mm), with or without precoating of the tube with type-1 collagen. PPACK (30 muM)-anticoagulated blood with H-3-serotonin prelabeled platelets was perfused (flow rate: 30 ml/min, 90 s) over the stents. Platelet deposition was assessed by scintillation counting and morphology by scanning electron microscopy (SEM). To examine coagulation activation, plasma prothrombin fragments (F1+2) were measured before and after the perfusion. Protein deposition on PLA/SS stents was assessed at augmented shear forces mimicking coronary flow (rate: 60 ml/min, 60 s) under minimal anticoagulation (PPACK 1 muM). More platelets deposited on PLA stents than on SS stents under all study conditions (p < 0.03). Under anticoagulation (PPACK 30 muM) the generation of F1+2 remained unaltered. Under higher flow rate and limited anticoagulation SS stents accumulated 3.27 +/- 0.75 mug and PLA stents 5.25 +/- 1.74 mug of protein (Mean +/-SD, p < 0.95). Among all biodegradable stents, the braided PLA stent coated with PCL-PLA-heparin accumulated the fewest platelets (p < 0.02). In SEM, signs of platelet activation on braided heparin-coated PLA stents, when compared with uncoated braided PLA/SS stents, appeared modest. In conclusion, PCL-PLA-heparin coating of biodegradable stents may enhance their hemocompatibility, expressed by less platelet deposition. Nevertheless, materials, design, and coating techniques of biodegradable stents must be further developed.
引用
收藏
页码:1394 / 1401
页数:8
相关论文
共 51 条
[1]   Inhibition of neointima formation after experimental coronary artery stenting -: A new biodegradable stent coating releasing hirudin and the prostacyclin analogue iloprost [J].
Alt, E ;
Haehnel, I ;
Beilharz, C ;
Prietzel, K ;
Preter, D ;
Stemberger, A ;
Fliedner, T ;
Erhardt, W ;
Schömig, A .
CIRCULATION, 2000, 101 (12) :1453-1458
[2]   Optimal heparin surface concentration and antithrombin binding capacity as evaluated with human non-anticoagulated blood in vitro [J].
Andersson, J ;
Sanchez, J ;
Ekdahl, KN ;
Elgue, G ;
Nilsson, B ;
Larsson, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (02) :458-466
[3]   Orthopaedic applications for PLA-PGA biodegradable polymers [J].
Athanasiou, KA ;
Agrawal, CM ;
Barber, FA ;
Burkhart, SS .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (07) :726-737
[4]   DECREASED PLATELET DEPOSITION AND SMOOTH-MUSCLE CELL-PROLIFERATION AFTER INTRAMURAL HEPARIN DELIVERY WITH HYDROGEL-COATED BALLOONS [J].
AZRIN, MA ;
MITCHEL, JF ;
FRAM, DB ;
PEDERSEN, CA ;
CARTUN, RW ;
BARRY, JJ ;
BOW, LM ;
WATERS, DD ;
MCKAY, RG .
CIRCULATION, 1994, 90 (01) :433-441
[5]  
BAHAPULLE MN, 2002, CIRCULATION 2, V106, P2859
[6]   Heparin coating of tantalum coronary stents reduces surface thrombin generation but not factor IXa generation [J].
Blezer, R ;
Cahalan, L ;
Cahalan, PT ;
Lindhout, T .
BLOOD COAGULATION & FIBRINOLYSIS, 1998, 9 (05) :435-440
[7]  
Blezer R, 1997, J BIOMED MATER RES, V37, P108, DOI 10.1002/(SICI)1097-4636(199710)37:1<108::AID-JBM13>3.0.CO
[8]  
2-C
[9]   Bypass surgery versus stenting for the treatment of multivessel disease in patients with unstable angina compared with stable angina [J].
de Feyter, PJ ;
Serruys, PW ;
Unger, F ;
Beyar, R ;
de Valk, V ;
Milo, S ;
Simon, R ;
Regensburger, D ;
Crean, PA ;
McGovern, E ;
van den Heuvel, P ;
van Cauwelaert, C ;
Penn, I ;
Tyers, GFO ;
Lindeboom, W .
CIRCULATION, 2002, 105 (20) :2367-2372
[10]  