Computerized physician order entry and online decision support

被引:45
作者
Handler, JA
Feied, CF
Coonan, K
Vozenilek, J
Gillam, M
Peacock, PR
Sinert, R
Smith, MS
机构
[1] Northwestern Univ, Sch Med, Chicago, IL USA
[2] Inst Med Informat, Washington, DC USA
[3] Univ Utah, Sch Med, Salt Lake City, UT USA
[4] Evanston Northwestern Healthcare, Evanston, IL USA
[5] Suny Downstate Med Ctr, Brooklyn, NY 11203 USA
[6] MedStar Hlth, Washington, DC USA
关键词
computerized physician order entry; decision support systems; emergency department;
D O I
10.1197/j.aem.2004.08.007
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Computerized physician order entry (CPOE) and decision support systems (DSS) can reduce certain types of error but often slow clinicians and may increase other types of error. The net effect of these systems on an emergency department (ED) is unknown. The consensus participants combined published evidence with expert opinion to outline recommendations for success. These include seamless integration of CPOE and DSS into systems and workflow; ensuring access to Internet-based and other online support material in the clinical arena; designing systems specifically for the ED and measuring their impact to ensure an overall benefit; ensuring that CPOE systems provide error and interaction checking and facilitate weight- and physiology-based dosing; using interruptive alerts only for the highest-severity events; providing a simple, vendor-independent interface for institutional customization of CPOE alert thresholds; maximizing the use of automated systems and passive data capture; and ensuring the widespread availability of CPOE and DSS using secure wireless and portable technologies where appropriate. Decisions regarding CPOE and DSS in the ED should be guided by the ED chair or designee. Much of what is believed to be true regarding CPOE and DSS has not been adequately studied. Additional CPOE and DSS research is needed quickly, and this research should receive funding priority. DSS and CPOE hold great promise to improve patient care, but not all systems are equal. Evidence must guide these efforts, and the measured outcomes must consider the many factors of quality care.
引用
收藏
页码:1135 / 1141
页数:7
相关论文
共 62 条
[1]  
ABOOKIRE SA, 2002, P AMIA S, P2
[2]   General practitioners' perceptions of the pharmaceutical decision-support tools in their prescribing software [J].
Ahearn, MD ;
Kerr, SJ .
MEDICAL JOURNAL OF AUSTRALIA, 2003, 179 (01) :34-37
[3]   Evaluating the impact of information technology on medication errors: A simulation [J].
Anderson, JG ;
Jay, SJ ;
Anderson, M ;
Hunt, TJ .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2003, 10 (03) :292-293
[4]  
Aronsky D, 1999, J AM MED INFORM ASSN, P197
[5]   Some unintended consequences of information technology in health care: The nature of patient care information system-related errors [J].
Ash, JS ;
Berg, M ;
Coiera, E .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2004, 11 (02) :104-112
[6]   Effect of computerized physician order entry and a team intervention on prevention of serious medication errors [J].
Bates, DW ;
Leape, LL ;
Cullen, DJ ;
Laird, N ;
Petersen, LA ;
Teich, JM ;
Burdick, E ;
Hickey, M ;
Kleefield, S ;
Shea, B ;
Vander Vliet, M ;
Seger, DL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (15) :1311-1316
[7]   The impact of computerized physician order entry on medication error prevention [J].
Bates, DW ;
Teich, JM ;
Lee, J ;
Seger, D ;
Kuperman, GJ ;
Ma'Luf, N ;
Boyle, D ;
Leape, L .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1999, 6 (04) :313-321
[8]  
Bauer BA, 2002, AMIA 2002 SYMPOSIUM, PROCEEDINGS, P31
[9]   A neural network aid for the early diagnosis of cardiac ischemia in patients presenting to the emergency department with chest pain [J].
Baxt, WG ;
Shofer, FS ;
Sites, FD ;
Hollander, JE .
ANNALS OF EMERGENCY MEDICINE, 2002, 40 (06) :575-583
[10]   Computerized physician order entry: Helpful or harmful? [J].
Berger, RG ;
Kichak, JP .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2004, 11 (02) :100-103