Accuracy and reproducibility of manual and semiautomated quantification of MS lesions by MRI

被引:84
作者
Ashton, EA
Takahashi, C
Berg, MJ
Goodman, A
Totterman, S
Ekholm, S
机构
[1] Univ Rochester, Med Ctr, Dept Radiol, Rochester, NY 14642 USA
[2] Univ Rochester, Med Ctr, Dept Neurol, Rochester, NY 14642 USA
关键词
multiple sclerosis; volume measurement; lesion quantification; multispectral MRI; reproducibility;
D O I
10.1002/jmri.10258
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To evaluate the accuracy, reproducibility, and speed of two semiautomated methods for quantifying total white matter lesion burden in multiple sclerosis (MS) patients with respect to manual tracing and to other methods presented in recent literature. Materials and Methods: Two methods involving the use of MRI for semiautomated quantification of total lesion burden in MS patients were examined. The first method, geometrically constrained region growth (GEORG), requires user specification of lesion location. The second technique, directed multispectral segmentation (DMSS), requires only the location of a single exemplar lesion. Test data sets included both clinical MS data and MS brain phantoms. Results: The mean processing times were 60 minutes for manual tracing, 10 minutes for region growth, and 3 minutes for directed segmentation. Intra- and interoperator coefficients of variation (CVs) were 5.1% and 16.5% for manual tracing, 1.4% and 2.3% for region growth, and 1.5% and 5.2% for directed segmentation. The average deviations from manual tracing were 9% for region growth and 5.7% for directed segmentation. Conclusion: Both semiautomated methods were shown to have a significant advantage over manual tracing in terms of speed and precision. The accuracy of both methods was acceptable, given the high variability of the manual results.
引用
收藏
页码:300 / 308
页数:9
相关论文
共 24 条
[1]
Alfano B, 2000, J MAGN RESON IMAGING, V12, P799, DOI 10.1002/1522-2586(200012)12:6<799::AID-JMRI2>3.0.CO
[2]
2-#
[3]
Ashton E, 2001, COMP MED SY, P300, DOI 10.1109/CBMS.2001.941736
[4]
Detection of subpixel anomalies in multispectral infrared imagery using an adaptive Bayesian classifier [J].
Ashton, EA .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1998, 36 (02) :506-517
[5]
Multialgorithm solution for automated multispectral target detection [J].
Ashton, EA .
OPTICAL ENGINEERING, 1999, 38 (04) :717-724
[6]
A novel volumetric feature extraction technique with applications to MR images [J].
Ashton, EA ;
Parker, KJ ;
Berg, MJ ;
Chen, CW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (04) :365-371
[7]
Segmentation and measurement of brain structures in MRI including confidence bounds [J].
Ballester, MAG ;
Zisserman, A ;
Brady, M .
MEDICAL IMAGE ANALYSIS, 2000, 4 (03) :189-200
[8]
BESAG J, 1986, J R STAT SOC B, V48, P259
[9]
COMPUTER-ASSISTED REGISTRATION, SEGMENTATION, AND 3D RECONSTRUCTION FROM IMAGES OF NEURONAL TISSUE-SECTIONS [J].
CARLBOM, I ;
TERZOPOULOS, D ;
HARRIS, KM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :351-362
[10]
Cocosco Chris A., 1997, NEUROIMAGE, V5, P425