Off-line capillary electrophoresis/fully automated nanoelectrospray chip quadrupole time-of-flight mass spectrometry and tandem mass spectrometry for glycoconjugate analysis

被引:28
作者
Bindila, L [1 ]
Almeida, R [1 ]
Sterling, A [1 ]
Allen, M [1 ]
Peter-Katalinic, J [1 ]
Zamfir, A [1 ]
机构
[1] Univ Munster, Inst Med Phys & Biophys, D-48149 Munster, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 10期
关键词
capillary electrophoresis; chip nanoelectrospray ionization; quadrupole time-of-flight mass spectrometry; automation; glycoconjugates;
D O I
10.1002/jms.707
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Implementation and optimization of an off-line capillary electrophoresis (CE)/(-)nanoESIchip-quadrupole time-of-flight (QTOF) mass spectrometric (MS) and tandem MS system for compositional mapping and structural investigation of components in complex carbohydrate mixtures is described. The approach was developed for glycoscreening and applied to O-glycosylated peptides from urine of a patient suffering from alpha-N-acetylhexosaminidase deficiency, known as Schindler's disease. The fundamental issue of sensitivity, previously representing a serious drawback of the off-line CE/MS analysis, could be positively addressed by the off-line conjunction of CE with automated chip-based ESI-QTOF-MS to provide flexibility for CE/chip MS coupling and enhance structural elucidation of single components in heterogeneous mixtures. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1190 / 1201
页数:12
相关论文
共 47 条
[1]   Improved capillary electrophoretic separation and mass spectrometric detection of oligosaccharides [J].
An, HJ ;
Franz, AH ;
Lebrilla, CB .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1004 (1-2) :121-129
[2]  
Bindila L, 2002, J SEP SCI, V25, P1101, DOI 10.1002/1615-9314(20021101)25:15/17<1101::AID-JSSC1101>3.0.CO
[3]  
2-J
[4]  
BINDILA L, UNPUB
[5]   Determination of carbohydrates in juices by high-performance liquid capillary electrophoresis, chromatography, and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry [J].
Cabálková, J ;
Zídková, J ;
Pribyla, L ;
Chmelík, J .
ELECTROPHORESIS, 2004, 25 (03) :487-493
[6]   ALPHA-N-ACETYLGALACTOSAMINIDASE DEFICIENCY WITH MILD CLINICAL MANIFESTATIONS AND DIFFICULT BIOCHEMICAL-DIAGNOSIS [J].
DEJONG, J ;
VANDENBERG, C ;
WIJBURG, H ;
WILLEMSEN, R ;
VANDIGGELEN, O ;
SCHINDLER, D ;
HOEVENAARS, F ;
WEVERS, R .
JOURNAL OF PEDIATRICS, 1994, 125 (03) :385-391
[7]   Microchannel wall coatings for protein separations by capillary and chip electrophoresis [J].
Doherty, EAS ;
Meagher, RJ ;
Albarghouthi, MN ;
Barron, AE .
ELECTROPHORESIS, 2003, 24 (1-2) :34-54
[8]   A SYSTEMATIC NOMENCLATURE FOR CARBOHYDRATE FRAGMENTATIONS IN FAB-MS MS SPECTRA OF GLYCOCONJUGATES [J].
DOMON, B ;
COSTELLO, CE .
GLYCOCONJUGATE JOURNAL, 1988, 5 (04) :397-409
[9]   Sialylation analysis of O-glycosylated sialylated peptides from urine of patients suffering from Schindler's disease by Fourier transform ion cyclotron resonance mass spectrometry and sustained off-resonance irradiation collision-induced dissociation [J].
Froesch, M ;
Bindila, L ;
Zamfir, A ;
Peter-Katalinic, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (24) :2822-2832
[10]   Interfaces for coupled liquid-phase separation/mass spectrometry techniques.: An update on recent developments [J].
Gelpí, E .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (03) :241-253