A phase I study of oxidized raffinose cross-linked human hemoglobin

被引:82
作者
Carmichael, FJL
Ali, ACY
Campbell, JA
Langlois, SF
Biro, GP
Willan, AR
Pierce, CH
Greenburg, AG
机构
[1] Hemosol Inc, Clin Affairs Div, Toronto, ON M9W 4Z4, Canada
[2] LAB Pharmacol Res Int, Montreal, PQ, Canada
关键词
o-raffinose cross-linked human hemoglobin; hemoglobin solution; blood substitute; Hemolink; hemodynamic; pulmonary; liver; pancreas; renal; clinical chemistry;
D O I
10.1097/00003246-200007000-00017
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the safety of oxidized-raffinose crosslinked human hemoglobin, Hemolink, in normal healthy volunteers. Design: Randomized, placebo-controlled, double-blind study. Setting: Clinical research facility of a contract research organization. Patients: Forty-two healthy adult male volunteers of which 33 received Hemolink, Interventions: Oxidized-raffinose cross-linked and polymerized hemoglobin as a 10% (w/v) solution, in doses of 0.025-0.6 g/kg or an equivalent volume of lactated Ringer's solution, was infused intravenously on day 1, and subjects were monitored for 3 days in the clinical facility with less than or equal to 6 wks follow-up. Major organ function was assessed pre- and postinfusion, by hemodynamic, electrocardiographic, pulmonary function, and clinical chemistry measurements. Measurements and Main Results: Doses of 1.7-42 g of hemoglobin were administered with no serious adverse events noted. Abdominal pain of moderate to severe intensity was seen in some subjects at doses >0.4 g/kg and was alleviated with smooth muscle relaxants. There was a dose-dependent increase in mean arterial pressure with a plateau of approximately 14% above baseline at 0.1 g/kg. There was a concomitant reduction in heart rate, with no electrocardiographic abnormalities found. Respiratory function was not affected. There was a dose-dependent increase in serum bilirubin with values above the upper limit of normal at doses of greater than or equal to 0.4 g/kg. Small increases in aspartate aminotransferase and alanine aminotransferase were noted in some patients, whereas alkaline phosphatase and gamma-glutamyltransferase remained in the normal range. Serum amylase concentrations were normal in 31 of 33 patients receiving Hemolink, whereas lipase was within the normal range in 21 of 33 patients. LDH was increased in a dose-dependent fashion. Two patients had increased creatine kinase concentrations, with a normal creatine kinase-MB mass fraction. All hematologic variables were within the normal range. The half-life of the oligomeric (>64 kDa) fraction of Hemolink was 18-20 hrs, Conclusion: Oxidized-raffinose cross-linked hemoglobin, Hemolink, at doses less than or equal to 0.6 g/kg were well tolerated in healthy volunteers with no evidence of organ dysfunction. Further investigation of its potential use in surgical and trauma settings appears warranted.
引用
收藏
页码:2283 / 2292
页数:10
相关论文
共 34 条
[1]  
ADAMSON JG, 1997, BLOOD SUBSTITUTES PR, P62
[2]  
ADAMSON JG, 1997, FUNDAMENTAL PRINCIPL, P335
[3]  
Ali ACY, 1997, CLIN CHEM, V43, P1794
[4]   CLINICAL EXPERIENCE WITH HEMOGLOBIN-SALINE SOLUTIONS [J].
AMBERSON, WR ;
JENNINGS, JJ ;
RHODE, CM .
JOURNAL OF APPLIED PHYSIOLOGY, 1949, 1 (07) :469-489
[5]   EFFECTS OF ANESTHESIA ON BAROREFLEX CONTROL OF HEART RATE IN MAN [J].
BRISTOW, JD ;
PRYSROBE.C ;
FISHER, A ;
PICKERING, TG ;
SLEIGHT, P .
ANESTHESIOLOGY, 1969, 31 (05) :422-+
[6]   ASSESSMENT OF BLOOD SUBSTITUTES .2. IN-VITRO COMPLEMENT ACTIVATION OF HUMAN PLASMA AND BLOOD FOR SAFETY STUDIES IN RESEARCH, DEVELOPMENT, INDUSTRIAL-PRODUCTION AND PRECLINICAL ANALYSIS [J].
CHANG, TMS ;
LISTER, CW .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 1994, 22 (02) :171-180
[7]   Effects of recombinant human hemoglobin on opossum sphincter of Oddi motor function in vivo and in vitro [J].
Cullen, JJ ;
Conklin, JL ;
Murray, J ;
Ledlow, A ;
Rosenthal, G .
DIGESTIVE DISEASES AND SCIENCES, 1996, 41 (02) :289-294
[8]   Blood substitutes: Fluids, drugs, or miracle solutions? [J].
Dietz, NM ;
Joyner, MJ ;
Warner, MA .
ANESTHESIA AND ANALGESIA, 1996, 82 (02) :390-405
[9]  
FEOLA M, 1988, SURG GYNECOL OBSTET, V166, P211
[10]  
Gould SA, 1996, WORLD J SURG, V20, P1200