Treatment of high-temperature rinsing water from a degreasing plant by reverse osmosis

被引:11
作者
Jonsson, AS [1 ]
Wennerbeck, J [1 ]
机构
[1] Univ Lund, Dept Chem Engn 1, SE-22100 Lund, Sweden
关键词
reverse osmosis; high-temperature; RO; degreasing solution;
D O I
10.1016/S0011-9164(98)00009-5
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the manufacture of heat-exchangers, it is of great importance that the heat-exchanger plates be thoroughly cleaned before being sealed. At a Swedish heat-exchanger manufacturer, oil, grease and other impurities are removed in a washing plant consisting of three stages: a degreasing tank and two rinsing tanks. The possibility of improving the cleanliness of the heat-exchanger plates, without increasing the need for fresh water, by treating the rinsing water in a reverse osmosis (RO) plant, was studied in this investigation. A new, high-temperature-resistant, thin-film RO membrane from Osmonics-Desal was used in the experiments. The influence of a lubricant, based on a block copolymer, and an alkaline degreasing agent on the membrane performance was studied. The flux reduction of a model rinsing solution with time was moderate. The flux after 500 h of continuous treatment at 65 degrees C and 4.0 MPa was 351/m(2) h, and the permeate quality fulfilled the demands of the heat-exchanger manufacturer.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 5 条
[1]  
DENYER M, 1993, FINISHING, V17, P32
[2]  
LINDSEY TC, 1994, J AIR WASTE MANAGE, V44, P697
[3]  
SCHWERING H, 1993, PLAT SURF FINISH, V80, P56
[4]   New techniques for extreme conditions: High temperature reverse osmosis and nanofiltration [J].
Snow, MJH ;
deWinter, D ;
Buckingham, R ;
Campbell, J ;
Wagner, J .
DESALINATION, 1996, 105 (1-2) :57-61
[5]  