Cetylpyridinium-iodomercurate PVC membrane ion selective electrode for the determination of cetylpyridinium cation in Ezafluor mouth wash and as a detector for some potentiometric titrations

被引:44
作者
Abbas, MN [1 ]
Mostafa, GAE [1 ]
Homoda, AMA [1 ]
机构
[1] Natl Res Ctr, Microanalyt Lab, Cairo, Egypt
关键词
PVC membrane electrode; cetylpyridinium; iodomercurate;
D O I
10.1016/S0039-9140(00)00496-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric method is described for the determination of cetylpyridinium (CP) cation using a polyvinyl chloride powder (PVC) membrane sensor based on CP-iodomercurate ion pair as an electroactive material. The sensor shows a linear response for CP ion over the concentration range of 2 x 10(-6)-1 x 10(-3) M at 25 degreesC. The electrode posses a sub-Nernstian slope of 29.0 +/- 0.4 mV decade(-1), which has been thoroughly discussed. The electrode shows a fast potential response of similar to 50 s, which is almost constant over a pH range of 3.0-6.0. Selectivity coefficient data for some common ions show negligible interference, however, cetyltrimethylammonium bromide (CTMAB) interferes significantly. An average recovery of 98.8% for CP with an average relative standard deviation (R.S.D.) of 1.2% has burn achieved. The determination of CPC in Ezafluor mouth wash gave result that compare favorably with those obtained by the British Pharmacopoeia method. The CP electrode has been utilized as an end point indicator electrode in potentiometric titration of some anions, and applied for the determination of anionic surfactants in some commercial detergents and waste water. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:425 / 432
页数:8
相关论文
共 30 条
[1]   Study of the aggregation of nonylammonium chloride in aqueous solutions of sodium chloride by vapor pressure osmometry [J].
Ballesteros, M ;
Coronel, C ;
Galera-Gómez, PA .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1999, 150 (1-3) :143-149
[2]  
BRENN DGP, 1995, ANAL CHEM, V67, P4210
[3]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[4]  
BUSCHMANN N, 1993, TENSIDE, V29, P128
[5]  
Campanella L, 1996, ANALUSIS, V24, P387
[6]  
DAVIES JEW, 1973, LAB PRACT, V22, P20
[7]  
Egorov VV, 1996, J ANAL CHEM+, V51, P986
[8]  
FUERSTENAU DW, 1999, COLLOID SURFACE A, V146, P107
[9]   RAPID SCREENING METHOD FOR DITALLOWDIMETHYLAMMONIUM CHLORIDE AT THE LOW PPB LEVEL IN SURFACE-WATER USING SOLID-PHASE EXTRACTION AND NORMAL-PHASE LIQUID-CHROMATOGRAPHY WITH ONLINE POSTCOLUMN ION-PAIR EXTRACTION AND FLUORESCENCE DETECTION [J].
GORT, SM ;
HOGENDOORN, EA ;
BAUMANN, RA ;
VANZOONEN, P .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 53 (04) :289-296
[10]  
HASSAN SSM, 1988, ANALYST, V113, P1079