ECT imaging of three-phase fluidized bed based on three-phase capacitance model

被引:68
作者
Warsito, W [1 ]
Fan, LS [1 ]
机构
[1] Ohio State Univ, Dept Chem Engn, Koffolt Labs, Columbus, OH 43210 USA
关键词
electrical capacitance tomography; bubble column; three-phase fluidized bed; three-phase capacitance model; gas holdup; solids fraction;
D O I
10.1016/S0009-2509(02)00613-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, the electrical capacitance tomography (ECT) with neural network multi-criteria optimization image reconstruction technique (NN-MOIRT), early developed by the authors, is applied to imaging bubble column and three-phase fluidized bed systems in the real time manner. Air, norpar (paraffin) and glass-beads are used as the gas, liquid, and solid phases, respectively. A three-phase capacitance model coupled with a two-region model is proposed to attain the gas holdup and the solids fraction from the permittivity maps of the three-phase system. The two-region model assumes that the solids fraction in the emulsion phase in the no bubble region is the same as in the bubble region. The three-phase capacitance model combines series and parallel capacitance connections among gas, liquid and solid components to relate the three-phase permittivity to each phase holdup. A direct image calculation to obtain the gas holdup from the permittivity map of the three-phase system is also performed by determining the permittivity threshold for the gas bubbles, Comparisons of the gas holdup obtained by ECT with that obtained from liquid head measurement showed a good agreement, validating the applicability of the model and its associated image calculation. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:823 / 832
页数:10
相关论文
共 7 条
[1]  
GEORGE DL, 2000, SAND20000441
[2]   A dual sensor flow imaging tomographic system [J].
Johansen, GA ;
Froystein, T ;
Hjertaker, BT ;
Olsen, O .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (03) :297-307
[3]   Cross-sectional distributions of gas and solid holdups in slurry bubble column investigated by ultrasonic computed tomography [J].
Warsito ;
Ohkawa, M ;
Kawata, N ;
Uchida, S .
CHEMICAL ENGINEERING SCIENCE, 1999, 54 (21) :4711-4728
[4]   Measurement of real-time flow structures in gas-liquid and gas-liquid-solid flow systems using electrical capacitance tomography (ECT) [J].
Warsito, W ;
Fan, LS .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (21-22) :6455-6462
[5]   Neural network based multi-criterion optimization image reconstruction technique for imaging two- and three-phase flow systems using electrical capacitance tomography [J].
Warsito, W ;
Fan, LS .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (12) :2198-2210
[6]  
Williams R.A., 1995, PROCESS TOMOGRAPHY P
[7]   ELECTRICAL CAPACITANCE TOMOGRAPHY FOR FLOW IMAGING - SYSTEM MODEL FOR DEVELOPMENT OF IMAGE-RECONSTRUCTION ALGORITHMS AND DESIGN OF PRIMARY SENSORS [J].
XIE, CG ;
HUANG, SM ;
HOYLE, BS ;
THORN, R ;
LENN, C ;
SNOWDEN, D ;
BECK, MS .
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1992, 139 (01) :89-98