Flow rate pressure drop relation in coronary angioplasty: Catheter obstruction effect

被引:61
作者
Back, LH [1 ]
Kwack, EY [1 ]
Back, MR [1 ]
机构
[1] UNIV CALIF LOS ANGELES,HARBOR MED CTR,DEPT SURG,TORRANCE,CA 90509
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1996年 / 118卷 / 01期
关键词
D O I
10.1115/1.2795949
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Quantitative methods to measure the hemodynamic consequences of various endovascular interventions including balloon angioplasty are limited. Catheters measuring translesional pressure drops during balloon angioplasty procedures can cause flow blockage and thus inaccurate estimates of pre- and post-intervention flow rates. The purpose of this investigation was to examine the influence of the presence and size of an angioplasty catheter on measured mean pressure gradients across human coronary artery stenoses. Analytical flow modeling and in vitro experimental evidence, coupled with angiographic data on the dimensions and shape of stenotic vessel segments before and after angioplasty, indicated significant flow blockage effects with the catheter present.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 21 条
[1]   MEASUREMENT OF TRANSSTENOTIC PRESSURE-GRADIENT DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
ANDERSON, HV ;
ROUBIN, GS ;
LEIMGRUBER, PP ;
COX, WR ;
DOUGLAS, JS ;
KING, SB ;
GRUENTZIG, AR .
CIRCULATION, 1986, 73 (06) :1223-1230
[2]  
Back L.H, 1992, ADV BIOENG, V22, P337
[3]   ESTIMATED MEAN FLOW RESISTANCE INCREASE DURING CORONARY-ARTERY CATHETERIZATION [J].
BACK, LH .
JOURNAL OF BIOMECHANICS, 1994, 27 (02) :169-175
[4]  
BACK MR, UNPUB HEMODYNAMIC CO
[5]  
Cavaye D M, 1992, J Clin Laser Med Surg, V10, P349
[6]   EXPERIMENTAL-STUDY OF PULSATILE AND STEADY FLOW THROUGH A SMOOTH TUBE AND AN ATHEROSCLEROTIC CORONARY-ARTERY CASTING OF MAN [J].
CHO, YI ;
BACK, LH ;
CRAWFORD, DW ;
CUFFEL, RF .
JOURNAL OF BIOMECHANICS, 1983, 16 (11) :933-946
[7]   PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN [J].
COLE, JS ;
HARTLEY, CJ .
CIRCULATION, 1977, 56 (01) :18-25
[8]   FLOW-DEPENDENT CORONARY-ARTERY DILATATION IN HUMANS [J].
DREXLER, H ;
ZEIHER, AM ;
WOLLSCHLAGER, H ;
MEINERTZ, T ;
JUST, H ;
BONZEL, T .
CIRCULATION, 1989, 80 (03) :466-474
[9]  
Emanuelsson Hakan, 1993, Journal of the American College of Cardiology, V21, p340A
[10]   PHASIC PRESSURE-GRADIENTS ACROSS CORONARY AND RENAL-ARTERY STENOSES IN HUMANS [J].
GANZ, P ;
HARRINGTON, DP ;
GASPAR, J ;
BARRY, WH .
AMERICAN HEART JOURNAL, 1983, 106 (06) :1399-1406