Recent applications in nanoliquid chromatography

被引:108
作者
Hernandez-Borges, Javier [1 ]
Aturki, Zeineb [1 ]
Rocco, Anna [1 ]
Fanali, Salvatore [1 ]
机构
[1] CNR, Ist Metodol Chim, Area Ric Roma 1, I-00016 Rome, Italy
关键词
applications; chiral; environmental; nanoliquid chromatography; pharmaceutical;
D O I
10.1002/jssc.200700061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Since its first introduction by Karlsson and Novotny in 1988 nano-LC has emerged as a complementary and/or competitive separation method to conventional HPLC, offering several advantages such as higher efficiency, ability to work with minute sample sizes and lower consumption of mobile phases, and better compatibility with MS, etc. Although its use was not so extended initially, in the last years new and interesting applications have appeared which deserve to be carefully considered. The aim of this review is therefore to provide an updated and critical survey of different nano-LC applications in analytical chemistry.
引用
收藏
页码:1589 / 1610
页数:22
相关论文
共 187 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P244, DOI 10.1002/(SICI)1096-9888(199904)34:4<244::AID-JMS775>3.0.CO
[2]  
2-0
[3]   Distinguishing and quantifying peptides and proteins containing D-amino acids by tandem mass spectrometry [J].
Adams, CM ;
Zubarev, RA .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4571-4580
[4]  
Alexander JN, 1998, RAPID COMMUN MASS SP, V12, P1187, DOI 10.1002/(SICI)1097-0231(19980915)12:17<1187::AID-RCM300>3.0.CO
[5]  
2-T
[6]   Evaluation of automated isocratic and gradient nano-liquid chromatography and capillary electrochromatography [J].
Alexander, JN ;
Poli, JB ;
Markides, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2398-2409
[7]   Comparison between different sheathless electrospray emitter configurations regarding the performance of nanoscale liquid chromatography-time-of-flight mass spectrometry analysis [J].
Amirkhani, A ;
Wetterhall, M ;
Nilsson, S ;
Danielsson, R ;
Bergquist, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :257-266
[8]   Temperature-programmed packed capillary liquid chromatography coupled to evaporative light-scattering detection and electrospray ionization time-of-flight mass spectrometry for characterization of high-molecular-mass hindered amine light stabilizers [J].
Andersen, T ;
Skuland, IL ;
Holm, A ;
Trones, R ;
Greibrokk, T .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) :49-56
[9]   Affinity chromatography with monolithic capillary columns - II. Polymethacrylate monoliths with immobilized lectins for the separation of glycoconjugates by nano-liquid affinity chromatography [J].
Bedair, M ;
El Rassi, Z .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :236-245
[10]   Affinity chromatography with monolithic capillary columns I. Polymethacrylate monoliths with immobilized mannan for the separation of mannose-binding proteins by capillary electrochromatography and nano-scale liquid chromatography [J].
Bedair, M ;
El Rassi, Z .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :177-186