Retrospective evaluation of commonly used equations to predict energy expenditure in mechanically ventilated, critically ill patients

被引:34
作者
Alexander, E
Susla, GM
Burstein, AH
Brown, DT
Ognibene, FP
机构
[1] Tampa Gen Hosp, Dept Pharm Serv, Tampa, FL 33601 USA
[2] VHA, Serv Pharm, N Potomac, MD USA
[3] Pfizer Global Res & Dev, Clin Sci, Groton, CT USA
[4] Natl Inst Hlth, Dept Crit Care Med, Warren G Magnuson Clin Ctr, Bethesda, MD USA
来源
PHARMACOTHERAPY | 2004年 / 24卷 / 12期
关键词
energy expenditure; critically ill; mechanically ventilated; predictive equations; indirect calorimetry; severity of illness;
D O I
10.1592/phco.24.17.1659.52342
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Study Objective. To determine which of four commonly used equations to estimate energy expenditure is precise and unbiased compared with energy expenditure as measured by indirect calorimetry. Design. Retrospective, observational study. Setting. Adult medical intensive care unit in a research hospital of the National Institutes of Health Clinical Center. Patients. Seventy-six adult, mechanically ventilated, critically ill patients. Intervention. Indirect calorimetry reports generated by the National Institutes of Health Critical Care Medicine Department's Metabolic Cart Consult Service were reviewed. Bias and precision of resting energy expenditure (REE) estimated by equations were computed using mean prediction error (ME) and root mean squared prediction error (MSE). Equations were considered precise if the 95% confidence interval for MSE was within 15% of the measured energy expenditure (MEE) determined by indirect calorimetry. Equations were considered unbiased if the 95% confidence interval for ME included zero. Paired t tests were used to compare estimated REE values for each predictive equation with MEE values determined by indirect calorimetry. Data were stratified into regions of bias using classification and regression tree analysis, as well as visual inspection of estimated REE-versus-MEE curves for each equation. Measurements and Main Results. The Harris-Benedict equation multiplied by an activity factor of 1.2 was unbiased and precise. The Ireton-Jones equation was precise but biased. The American College of Chest Physicians' consensus recommendation was biased and imprecise. The Harris-Benedict equation without an activity factor also demonstrated bias and imprecision. Conclusions. The Harris-Benedict equation multiplied by an activity factor of 1.2 is suitable for predicting REE and may be used in the absence of indirect calorimetry.
引用
收藏
页码:1659 / 1667
页数:9
相关论文
共 21 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]   Applied nutrition in ICU patients - A consensus statement of the American College of Chest Physicians [J].
Cerra, FB ;
Benitez, MR ;
Blackburn, GL ;
Irwin, RS ;
Jeejeebhoy, K ;
Katz, DP ;
Pingleton, SK ;
Pomposelli, J ;
Rombeau, JL ;
Shronts, E ;
Wolfe, RR ;
Zaloga, GP .
CHEST, 1997, 111 (03) :769-778
[3]  
DICKERSON RN, 1995, HOSP PHARM, V30, P724
[4]  
DIETRICH KA, 1989, J CRIT ILLNESS, V4, P65
[5]  
ELWYN DH, 1981, SURG CLIN N AM, V61, P545
[6]   Assessment of resting energy expenditure in mechanically ventilated patients [J].
Faisy, C ;
Guerot, E ;
Diehl, JL ;
Labrousse, J ;
Fagon, JY .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 78 (02) :241-249
[7]  
Flancbaum L, 1999, AM J CLIN NUTR, V69, P461
[8]   Predictive versus measured energy expenditure using limits-of-agreement analysis in hospitalized, obese patients [J].
Glynn, CC ;
Greene, GW ;
Winkler, MF ;
Albina, JE .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1999, 23 (03) :147-154
[9]  
GRANT JP, 1975, HDB TOTAL PARENTERAL, P12
[10]  
HARRIS JA, 1919, BIOMETRIC STUDY BASA, P223