Accuracy of determination of position and width of molecular groups in biological and lipid membranes via neutron diffraction

被引:19
作者
Gordeliy, VI
Chernov, NI
机构
[1] INST MAX VON LAUE PAUL LANGEVIN, LARGE SCALE STRUCT GRP, F-38042 GRENOBLE 9, FRANCE
[2] UNIV ALABAMA, DEPT MATH, BIRMINGHAM, AL 35294 USA
[3] JOINT INST NUCL RES, FRANK LAB NEUTRON PHYS, DUBNA 141980, MOSCOW DISTRICT, RUSSIA
来源
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY | 1997年 / 53卷
关键词
D O I
10.1107/S0907444997000826
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Neutron diffraction combined with the deuterium-labelled molecular groups of biological and model membrane components allows one to detect with high accuracy the structure of these objects. Experiments of this kind are only possible at unique high-flux neutron sources, and the planning of neutron-diffraction experiments must take into account some special requirements primarily related to the duration of the experiment and the accuracy of estimation of membrane structure parameters as a result of finite time of the measurements. This paper deals with the question of statistical accuracy of the position x(0) and width nu of the distribution of deuterium labels in membranes along the normal of their plane, which are determined in a neutron diffraction experiment. It is shown that the accuracy of x(0) and nu estimation does not depend on membrane constitution. It is dependent only on the scattering amplitude of the deuterium label, the label position x(0) and the distribution width nu. Analytic calculations show that the statistical errors Delta x(0) and Delta nu are inversely proportional to the scattering amplitude of the label and, as usual, to the square root of measurement time. The question of Delta x(0) and Delta nu dependence on the number of structure factors used in the calculations of x(0) and nu is also studied. It is shown that, the accuracy of x(0) estimation is approximately constant with down to four structure factors used, and, with the number of the factors below four, it deteriorates drastically. Analogous is the behaviour of Delta nu(h(max)) relation with one exception: abrupt deterioration of the accuracy occurs beginning with five structure factors used. One does not have to measure the highest diffraction reflections which takes a much longer time compared with the first ones. It is an important result. All the problems mentioned above have also been considered for the case of two different deuterium labels in membranes.
引用
收藏
页码:377 / 384
页数:8
相关论文
共 18 条