Fungal infections in ventricular assist devices

被引:14
作者
Goldberg, SP
Baddley, JW
Aaron, MF
Pappas, PG
Holman, WL
机构
[1] Univ Alabama, Dept Surg, Univ Stn, Birmingham, AL 35294 USA
[2] Univ Alabama, Dept Med, Birmingham, AL 35294 USA
关键词
D O I
10.1097/00002480-200011000-00035
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Device infections in patients supported by a mechanical circulatory support system remain an important problem, particularly as we enter the era of permanent device implantation. This article focuses on fungal infections that occur in patients with ventricular assist devices. The nature of fungal, especially Candida species, colonization and infection in severely ill, hospitalized patients will be described. information regarding the effect of the artificial surface-blood interface on the immune system's ability to combat fungal organisms will also be presented. Basic aspects of the fungal-host interaction serve as the foundation for a discussion of clinical management protocols for preventing and treating fungal infections in patients supported by a ventricular assist device.
引用
收藏
页码:S37 / S40
页数:4
相关论文
共 27 条
[1]
Activation-induced T-cell death and immune dysfunction after implantation of left-ventricular assist device [J].
Ankersmit, HJ ;
Tugulea, S ;
Spanier, T ;
Weinberg, AD ;
Artrip, JH ;
Burke, EM ;
Flannery, M ;
Mancini, D ;
Rose, EA ;
Edwards, NM ;
Oz, MC ;
Itescu, S .
LANCET, 1999, 354 (9178) :550-555
[2]
Fungal infection in surgical patients [J].
Dean, DA ;
Burchard, KW .
AMERICAN JOURNAL OF SURGERY, 1996, 171 (03) :374-382
[3]
Decruyenaere J, 1995, TRANSPLANT P, V27, P3515
[4]
Left ventricular assist system support is associated with persistent inflammation and temporary immunosuppression [J].
Deng, MC ;
Erren, M ;
Tjan, TDT ;
Tamminga, N ;
Werntze, B ;
Zimmermann, P ;
Weyand, M ;
Hammel, D ;
Schmidt, C ;
Scheld, HH .
THORACIC AND CARDIOVASCULAR SURGEON, 1999, 47 :326-331
[5]
FISHER SA, 1997, CLIN INFECT DIS, V24, P18
[6]
Gleason TG, 1997, ARCH SURG-CHICAGO, V132, P1197, DOI 10.1001/archsurg.1997.01430350047008
[7]
Goldstein D J, 1995, ASAIO J, V41, P873, DOI 10.1097/00002480-199510000-00010
[8]
Circulatory resuscitation with left ventricular assist device support reduces interleukins 6 and 8 levels [J].
Goldstein, DJ ;
Moazami, N ;
Seldomridge, JA ;
Laio, H ;
Ashton, RC ;
Naka, Y ;
Pinsky, DJ ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 1997, 63 (04) :971-974
[9]
Herrmann M, 1997, CIRCULATION, V95, P814
[10]
Infection during circulatory support with ventricular assist devices [J].
Holman, WL ;
Skinner, JL ;
Waites, KB ;
Benza, RL ;
McGiffin, DC ;
Kirklin, JK .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :711-716