Electrospray-atmospheric sampling glow discharge ionization source for the direct analysis of liquid samples

被引:11
作者
Dalton, CN [1 ]
Glish, GL [1 ]
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
关键词
D O I
10.1021/ac026087j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coupling electrospray with atmospheric sampling glow discharge ionization for the direct analysis of liquid-phase samples is demonstrated. Electrospray is utilized for nebulizing and transporting intact sample molecules into the glow discharge where ionization occurs through various pathways, including electron ionization and ion-molecule reactions with reagent ions. Reagent ions are formed through ionization of air molecules in an area of reduced pressure. The effects of discharge current, electrospray voltage, and solution flow rate on the absolute and relative ion intensities observed in the mass spectra are discussed. This technique is applicable to compounds containing various functional groups and encompassing a range of volatility. Analysis of organic compounds with varying volatility and polarity is discussed to illustrate the utility of this ionization technique.
引用
收藏
页码:1620 / 1627
页数:8
相关论文
共 45 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P157, DOI 10.1002/(SICI)1096-9888(199903)34:3<157::AID-JMS804>3.0.CO
[2]  
2-4
[3]   GAS-NEBULIZED DIRECT LIQUID INTRODUCTION INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
APFFEL, JA ;
BRINKMAN, UAT ;
FREI, RW ;
EVERS, EAIM .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2280-2284
[4]   Collision-induced signal enhancement:: A method to increase product ion intensities in MS/MS and MSn experiments [J].
Asam, MR ;
Ray, KL ;
Glish, GL .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1831-1837
[5]  
ASANO KG, 1990, SPECTROSC INT J, V6, P191
[6]   LIQUID CHROMATOGRAPHY MASS SPECTROMETRY INTERFACE .1. DIRECT INTRODUCTION OF LIQUID SOLUTIONS INTO A CHEMICAL IONIZATION MASS-SPECTROMETER [J].
BALDWIN, MA ;
MCLAFFER.FW .
ORGANIC MASS SPECTROMETRY, 1973, 7 (09) :1111-1112
[7]   THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLAKLEY, CR ;
VESTAL, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :750-754
[8]   CROSSED-BEAM LIQUID CHROMATOGRAPH MASS SPECTROMETER COMBINATION [J].
BLAKLEY, CR ;
MCADAMS, MJ ;
VESTAL, ML .
JOURNAL OF CHROMATOGRAPHY, 1978, 158 (OCT) :261-276
[9]   What can we learn from it? [J].
Bogaerts, A ;
Gijbels, R .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :A719-A727
[10]   ROLE OF GAS-DYNAMICS IN NEGATIVE-ION FORMATION IN AN ATMOSPHERIC SAMPLING GLOW-DISCHARGE IONIZATION SOURCE [J].
CHAMBERS, DM ;
MCLUCKEY, SA ;
GLISH, GL .
ANALYTICAL CHEMISTRY, 1993, 65 (06) :778-783